HVC-R 100/150 E-Bus Charger Installation Guide
Document: v0.4 / Document No.: TBA | Date: 11-08-2021 Page
77
of
131
Location of required terminal blocks
A
Terminal block
B
Interlock cable
1. Move the cable towards the terminal block (A).
2. Strip 11 mm of the insulation from the ends of
the White and Brown wires only!
3. Crimp a ferrule onto the ends of the White and Brown wires.
4. Ensure that the unused wires (green and yellow) are secured so that they cannot touch
metal parts.
5. Loosen the connector screws.
6. Insert the wires into the connectors, see table below:
Functional description
Connector
Wire color
Interlock In
X8-14
Brown
Interlock Out
X8-7
White
Interlock GND
X8-Shield (refer to the picture above)
Shield
See also Appendix F
Signal connection diagram
.
7. Tighten the connector screws with a tightening torque of 1.3 Nm.
Содержание HVC-R 100
Страница 1: ... INSTALLATION GUIDE HVC R 100 150 E Bus Charger Installation Guide for EU products Version 0 4 ...
Страница 122: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 122 of 131 ...
Страница 125: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 125 of 131 ...
Страница 131: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 131 of 131 NOTES ...