HVC-R 100/150 E-Bus Charger Installation Guide
Document: v0.4 / Document No.: TBA | Date: 11-08-2021 Page
21
of
131
2.2.4. Wall-mounting brackets for Dual Depot Charge Box safe wall fixing
The Dual Depot Charge Box (A) can be easily mounted onto a wall with wall mounting
brackets (B).
Wall mounting bracket
Amount
Part number
Description
1
*
ABB6AGC083492
Standard wall-mounting bracket (ABB)
(*)
pack quantity is 4
2.2.5. Communication ethernet cable
The CAN/Ethernet communication between the Power Cabinet and Dual Depot Charge Boxes
is achieved via an Ethernet cable.
If the cable is not supplied by ABB, then gland dimensions listed in section
Gland layout of the
Dual Depot Charge Box
on Page 89 must be followed. Please note that special precautions
should be taken, so that pre-fabricated the cable could pass through the gland (for example
order cable with M25 gland assembled on it). Another alternative could be to crimp the cable
on site after passing through the gland.
Cable length must be defined by the Contractor performing installation during site survey.
Amount
Part number
Description
1
Contact ABB for details
Ethernet (S/FTP, CAT6) with RJ45 connectors
Содержание HVC-R 100
Страница 1: ... INSTALLATION GUIDE HVC R 100 150 E Bus Charger Installation Guide for EU products Version 0 4 ...
Страница 122: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 122 of 131 ...
Страница 125: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 125 of 131 ...
Страница 131: ...HVC R 100 150 E Bus Charger Installation Guide Document v0 4 Document No TBA Date 11 08 2021 Page 131 of 131 NOTES ...