HVC-R 100/150 E-Bus Charger Installation Guide
Document: v0.4 / Document No.: TBA | Date: 11-08-2021 Page
119
of
131
8.4. Environment
Environment specification Power Cabinet
Ingression protection
IP54
Temperature range – Operation
-35 ºC to +45
⁰
C
Temperature range – Storage
-10 ºC to +70
⁰
C
Humidity
5 % to 95 %, RH – non-condensing
Airflow
1450 m
3
/h
Pressure drop
300 Pa
Altitude
2000 m (max.)
Storage conditions
Indoors, dry
Environment specification for the Dual Depot Charge Box
Ingression protection
IP65 (excluding charge cable)
Temperature range – Operation
-35 ºC to +55
⁰
C
Temperature range – Storage
-10 ºC to +70
⁰
C
Humidity
5 % to 95 %, RH – non-condensing
Altitude
2000 m (max.)
Storage conditions
Indoors, dry
CAUTION
Warranty
Warranty will be considered void if the HVC-R 100/150 E-Bus Charger is
damaged due to being stored inappropriately by the Customer.
8.5. Certifications
Certifications for complete system
CE
Declaration of Conformity HVC150: 20160609
Class of protection
1 with PE connection