64 Start-up
53.02 FBA DATA OUT2 12
(= Ref1 32bit)
Reference 1
53.04 FBA DATA OUT4 13
(= Ref2 32bit)
Reference 2
51.27 FBA PAR
REFRESH
REFRESH
Validates the FPBA-01
configuration parameter
settings.
10.01 EXT1 START
FUNC
FBA
Selects the fieldbus
interface as the source of
the start and stop
commands for external
control location 1.
22.01 SPEED FB SEL
Enc1 speed
2)
Selects the actual speed
measured by encoder 1 as
the speed feedback.
34.02 EXT1 MODE
1/2SEL
P.FBA MAIN
CW.26
Selects the source for
external 1 control mode 1/2
selection. Selection is done
by START_HOMING bit
(bit 26 in the fieldbus
Control word).
Mode 1: Position, Mode 2:
Homing
34.03 EXT1 CTRL
MODE1
Position
Selects position control as
the control mode 1 for
external control location 1.
34.04 EXT1 CTRL
MODE2
Homing
Selects homing control as
the control mode 2 for
external control location 1.
62.01 HOMING
METHOD
CAN Methodxx
Selects the homing mode.
Select the appropriate
CAN Method.
62.03 HOMING START
C.False
Selects the fieldbus as the
homing start source.
65.01 POS
REFSOURCE
Fieldbus
Position reference and
speed are read from the
fieldbus.
Drive parameter
Setting for
ACSM1 drives
Description
Содержание FPBA-01 PROFIBUS DP
Страница 1: ...Options for ABB drives converters and inverters User s manual FPBA 01 PROFIBUS DP adapter module ...
Страница 4: ......
Страница 10: ...10 Table of contents Document library on the Internet 195 ...
Страница 20: ...20 About the manual ...
Страница 26: ...26 Overview of the PROFIBUS network and the FPBA 01 module ...
Страница 30: ...30 Mechanical installation ...
Страница 91: ...Start up 91 8 Click Properties Network Settings and set baud rate ...
Страница 98: ...98 Start up ...
Страница 118: ...118 Communication profiles ...
Страница 178: ...178 Diagnostics ...
Страница 182: ...182 Technical data ...
Страница 190: ...190 Appendix A PROFIdrive parameters ...