Communication protocol 141
For a complete PROFIdrive parameter list, see
Note:
Continuous (cyclic) writing of PROFIdrive parameters should
be avoided as the values of these parameters are stored in the
flash memory of the adapter module. The estimated lifetime of the
flash memory is 100,000 program/erase cycles, and continuous
writing will cause the memory to fail prematurely.
PROFIdrive parameters
Index
Sub-index
Par. No
(Decimal)
Request label
Example
No.
393h
2h
915
2
R/W
6/7
6
3h
3
• • •
• • •
9h
9
394h
2h
916
2
R/W
6/7
7
3h
3
• • •
• • •
9h
9
396h
0h
918
R/W
1/2
3, 4
• • •
3B3h
0h
947
1
R
6
5
9h
9
11h
17
19h
25
21h
33
29h
41
• • •
3CCh
0h
972
R/W
1/2
3, 4