128 Communication protocol
7
DPV1_Status_1 (DP-V1 only)
x 0 x 0 0 x x x
Dis_Start_Control
(Disable Stop-Bit Control)
0 = Start bit monitoring in
receiver enabled
1 = Start bit monitoring in
receiver disabled
MSB
LSB
WD_Base
(Watchdog time base)
0 = 10 ms
1 = 1 ms
Dis_Stop_Control
(Disable Stop-Bit Control)
0 = Stop bit monitoring in
receiver enabled
1 = Stop bit monitoring in
receiver disabled
Reserved
Publisher_Enabled
.
Not supported.
0 = Slave not operated in DXB
Publisher mode
1 = Slave operated in DXB
Publisher mode
Fail_Safe
. Not supported.
DPV1_Enable
0 = Slave operated in DP
mode
1 = Slave operated in DP-V1
mode