3.4.3 Cleaning the Fan unit
Overview
Use this section to clean the fan unit.
Location
en0500001924
Fan holder with fan
A
Fan casing
B
Attachment screws M5x9, Fastite screw (4 pcs)
C
Required equipment
Note
Article number
Equipment
The contents are defined in section
Toolkits, DressPack/SpotPack on
page 335
.
3HAC17290-7
Standard toolkit
DressPack/SpotPack
-
Vacuum cleaner
Maintenance procedure
Note
Action
DANGER
Before any work inside the cabinet, please
observe the safety information in the sec-
tion
DANGER - Make sure that the main
power has been switched off
in the product
manual for the IRC5 controller.
1
Shown in the section
Remove the attachment screws holding the
fan casing.
2
Screw M5x9 Fastite (4 pcs)
Disconnect the fan connector.
3
Continues on next page
216
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
3 Maintenance
3.4.3 Cleaning the Fan unit
Содержание DressPack IRB 6640
Страница 1: ...ROBOTICS Product manual DressPack SpotPack IRB 6640 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 44: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 220: ...This page is intentionally left blank ...
Страница 324: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 364: ...This page is intentionally left blank ...
Страница 366: ...This page is intentionally left blank ...
Страница 369: ......