![ABB DressPack IRB 6640 Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/abb/dresspack-irb-6640/dresspack-irb-6640_product-manual_5004210.webp)
Inspection, water in and water return circuits
The procedure below describes how to inspect the water in and water return circuits.
Note
Action
Open the hand operated ball valve for water
inlet.
1
Open the water return valve on the water in
circuit.
2
Close the hand operated ball valve for water
outlet.
3
Retighten if necessary!
While the system is under pressure, check
if there are any leaks.
4
Reset the system.
5
210
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
3 Maintenance
3.3.3 Preventive inspection of Water and air unit
Continued