![ABB ACS320 series Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/abb/acs320-series/acs320-series_user-manual_2965070.webp)
70 Start-up
Changed parameters mode
To view (and edit) a listing of all parameters that have been changed from macro
default values, follow these steps:
Fault logger mode
Use the Fault logger mode to see drive fault history, fault state details and help for the
faults.
1. Select
FAULT LOGGER
in the MAIN MENU.
2. Press
ENTER
to see the latest faults (up to 10 faults, maximum).
3. Press
DETAIL
to see details for the selected fault.
• Details are available for the three latest faults.
4. Press
DIAG
to see the help description for the fault. See chapter
.
Note:
If a power off occurs, only the three latest faults will remain (with details only in
the first fault).
Drive parameter backup mode
Use the parameter backup mode to export parameters from one drive to another. The
parameters are uploaded from a drive to the control panel and downloaded from the
control panel to another drive. Two options are available:
Par backup mode
The Assistant control panel can store a full set of drive parameters.
The Par backup mode has these functions:
1
Select MENU to enter the menu.
2
Select CHANGED PAR with the
UP/DOWN buttons and select
ENTER.
3
A list of changed parameters is
displayed. Select EXIT to exit the
parameters mode.
0 A
0 %
0 mA
0.
0.
0.
0.0Hz
OFF
MENU
SP
PARAMETERS
ASSISTANTS
CHANGED PAR
EXIT
ENTER
OFF
MAIN MENU
3
1202 CONST SPEED 1
20.0 Hz
1203 CONST SPEED 2
1204 CONST SPEED 3
1304 MINIMUM AI2
CHANGED PAR
EXIT
EDIT
OFF
Содержание ACS320 series
Страница 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Страница 4: ......
Страница 18: ...18 Safety ...
Страница 28: ...28 Operation principle and hardware description ...
Страница 56: ...56 Electrical installation ...
Страница 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Страница 282: ...282 Actual signals and parameters ...
Страница 358: ...358 Fieldbus control ...
Страница 376: ...376 Fault tracing ...
Страница 382: ...382 Maintenance and hardware diagnostics ...
Страница 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Страница 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Страница 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Страница 412: ...412 Dimension drawings ...
Страница 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...
Страница 442: ...www abb com drives www abb com drivespartners 3AUA0000062599 Rev E EN EFFECTIVE 2016 07 05 Contact us 3AUA0000062599E ...