Technical data 389
Fuses and MMPs
Type
Fuses
MMPs
ACS320-
gG
UL Class T or
CC (600 V)
Frame
I
1N
MMP Type E
Min. Encl.
Vol.
4)
x = E/U
1)
A
min A
2)
max A
A
dm
3
in
3
1-phase U
N
= 200…240 V
(200, 208, 220, 230, 240 V)
01x-02A4-2
10
6
10
R0
6.1
MS132-6.3 & S1-M3-25
18.9
1152
01x-04A7-2
16
10
20
R1
11.4
MS165-16
3)
18.9
1152
01x-06A7-2 16/20*
15
25
R1
16.1
MS165-20
3)
18.9
1152
01x-07A5-2 20/25*
15
30
R2
16.8
MS165-20
3)
-
-
01x-09A8-2 25/35*
15
35
R2
21.0
MS165-25
3)
-
-
3-phase U
N
= 200
…
240 V
(200, 208, 220, 230, 240 V)
03x-02A6-2
10
3
10
R0
4.7
MS132-6.3 & S1-M3-25
18.9
1152
03x-03A9-2
10
6
10
R0
6.7
MS132-10 & S1-M3-25
18.9
1152
03x-05A2-2
10
6
15
R1
8.4
MS132-10 & S1-M3-25
18.9
1152
03x-07A4-2
16
10
15
R1
13.0
MS165-16
3)
18.9
1152
03x-08A3-2
16
10
15
R1
13.2
MS165-16
3)
18.9
1152
03x-10A8-2
16
15
20
R2
15.7
MS165-20
3)
-
-
03x-14A6-2
25
15
30
R2
23.9
MS165-25
3)
-
-
03x-19A4-2
25
20
35
R2
27.3
MS165-32
3)
-
-
03x-26A8-2
63
30
60
R3
45.0
MS165-54
3)
-
-
03x-34A1-2
80
35
80
R4
55.0
MS165-65
3)
-
-
03x-50A8-2
100
50
100
R4
76.0
MS495-90 & SK4 &
DX49
-
-
3-phase U
N
= 380... 480 V
(380, 400, 415 V)
(MMP ratings for 480Y/277V only)
03x-01A2-4
10
2
10
R0
2.2
MS132-2.5 & S1-M3-25
18.9
1152
03x-01A9-4
10
2
10
R0
3.6
MS132-4.0 & S1-M3-25
18.9
1152
03x-02A4-4
10
3
10
R1
4.1
MS132-6.3 & S1-M3-25
18.9
1152
03x-03A3-4
10
3
10
R1
6.0
MS132-6.3 & S1-M3-25
18.9
1152
03x-04A1-4
16
6
15
R1
6.9
MS132-10 & S1-M3-25
18.9
1152
03x-05A6-4
16
6
15
R1
9.6
MS132-10 & S1-M3-25
18.9
1152
03x-07A3-4
16
6
20
R1
11.6
MS165-16
3)
18.9
1152
03x-08A8-4
20
10
25
R1
13.6
MS165-16
3)
18.9
1152
03x-12A5-4
25
10
30
R3
18.8
MS165-20
3)
-
-
03x-15A6-4
35
15
35
R3
22.1
MS165-25
3)
-
-
03x-23A1-4
50
20
50
R3
30.9
MS165-42
3)
-
-
03x-31A0-4
80
25
80
R4
52.0
MS165-65
3)
-
-
03x-38A0-4
100
30
100
R4
61.0
MS165-65
3)
-
-
03x-44A0-4
100
35
100
R4
67.0
MS495-75 & SK4-11 &
DX49
-
-
3-phase U
N
= 380... 480 V
(440, 460, 480 V)
(MMP ratings for 480Y/277V only)
03x-01A2-4
10
2
10
R0
1.8
MS132-2.5 & S1-M3-25
18.9
1152
03x-01A9-4
10
2
10
R0
3.0
MS132-4.0 & S1-M3-25
18.9
1152
03x-02A4-4
10
3
10
R1
3.4
MS132-6.3 & S1-M3-25
18.9
1152
03x-03A3-4
10
3
10
R1
5.0
MS132-6.3 & S1-M3-25
18.9
1152
03x-04A1-4
16
6
15
R1
5.8
MS132-10 & S1-M3-25
18.9
1152
03x-05A6-4
16
6
15
R1
8.0
MS132-10 & S1-M3-25
18.9
1152
03x-07A3-4
16
6
20
R1
9.7
MS132-10 & S1-M3-25
18.9
1152
03x-08A8-4
20
10
25
R1
11.0
MS165-16
3)
18.9
1152
03x-12A5-4
25
10
30
R3
16.0
MS165-20
3)
-
-
Содержание ACS320 series
Страница 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Страница 4: ......
Страница 18: ...18 Safety ...
Страница 28: ...28 Operation principle and hardware description ...
Страница 56: ...56 Electrical installation ...
Страница 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Страница 282: ...282 Actual signals and parameters ...
Страница 358: ...358 Fieldbus control ...
Страница 376: ...376 Fault tracing ...
Страница 382: ...382 Maintenance and hardware diagnostics ...
Страница 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Страница 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Страница 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Страница 412: ...412 Dimension drawings ...
Страница 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...
Страница 442: ...www abb com drives www abb com drivespartners 3AUA0000062599 Rev E EN EFFECTIVE 2016 07 05 Contact us 3AUA0000062599E ...