![ABB ACS320 series Скачать руководство пользователя страница 361](http://html.mh-extra.com/html/abb/acs320-series/acs320-series_user-manual_2965361.webp)
Fault tracing 361
Alarm messages generated by the drive
CODE
ALARM
CAUSE
WHAT TO DO
2001
OVERCURRENT
bit 0
(programmable fault
function
Output current limit
controller is active.
Check motor load.
Check acceleration time (
and
Check motor and motor cable
(including phasing).
Check ambient conditions. Load
capacity decreases if installation site
ambient temperature exceeds 40 °C.
See section
.
2002
OVERVOLTAGE
bit 1
(programmable fault
function
DC overvoltage
controller is active.
Check deceleration time (
and
Check input power line for static or
transient overvoltage.
2003
UNDERVOLTAGE
bit 2
(programmable fault
function
DC undervoltage
controller is active.
Check input power supply.
2004
DIR LOCK
bit 3
Change of direction is
not allowed.
Check the settings of parameter
2005
IO COMM
bit 4
(programmable fault
function
Fieldbus
communication break
Check status of fieldbus
communication. See chapter
Check fault function parameter
settings.
Check connections.
Check if master can communicate.
2006
AI1 LOSS
bit 5
(programmable fault
function
Analog input AI1 signal
has fallen below limit
defined by parameter
Check fault function parameter
settings.
Check for proper analog control
signal levels.
Check connections.
2007
AI2 LOSS
bit 6
(programmable fault
function
Analog input AI2 signal
has fallen below limit
defined by parameter
Check fault function parameter
settings.
Check for proper analog control
signal levels.
Check connections.
2008
PANEL LOSS
bit 7
(programmable
fault function
Control panel selected
as active control
location for drive has
ceased
communicating.
Check panel connection.
Check fault function parameters.
Check control panel connector.
Refit control panel in mounting
platform.
If drive is in external control mode
(REM) and is set to accept start/stop,
direction commands or references via
and
settings.
Содержание ACS320 series
Страница 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Страница 4: ......
Страница 18: ...18 Safety ...
Страница 28: ...28 Operation principle and hardware description ...
Страница 56: ...56 Electrical installation ...
Страница 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Страница 282: ...282 Actual signals and parameters ...
Страница 358: ...358 Fieldbus control ...
Страница 376: ...376 Fault tracing ...
Страница 382: ...382 Maintenance and hardware diagnostics ...
Страница 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Страница 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Страница 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Страница 412: ...412 Dimension drawings ...
Страница 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...
Страница 442: ...www abb com drives www abb com drivespartners 3AUA0000062599 Rev E EN EFFECTIVE 2016 07 05 Contact us 3AUA0000062599E ...