Start-up 65
Status information
Top
. The top line of the LCD display shows the basic status information of the drive.
• HAND
–
Indicates that the drive control is local, that is, from the control panel.
• AUTO
–
Indicates that the drive control is remote, such as the basic I/O (X1) or
fieldbus.
• OFF – Indicates that the drive control is local and stopped.
•
–
Indicates the drive and motor rotation status as follows:
• Upper right
–
shows the active reference.
Middle
. Using
, the middle of the
LCD display can be configured to display:
• One to three parameter values
–
The default display
in milliamperes.
- Use parameters
, and
to select the parameters (from
) to display. Entering “parameter” 0100 results in no
parameter displayed. For example, if
= 0100, then only
the parameter specified by
appears in the Control panel display.
- You can also scale each parameter in the display, for example, to convert the
motor speed to a display of conveyor speed. Parameters
scale the
parameter specified by
, parameters
…
scale the parameter
specified by
, etc.
• A bar meter rather than one of the parameter values.
- Enable bar graph displays using parameters
,
and
.
Bottom.
The bottom of the LCD display shows:
• Lower corners
–
show the functions currently
assigned to the two soft keys.
• Lower middle
–
displays the current time (if configured to show the time).
Control panel display
Significance
Rotating arrow (clockwise or
counterclockwise)
• Drive is running and at setpoint
• Shaft direction is forward or reverse
Rotating dotted arrow blinking
Drive is running but not at setpoint
Stationary dotted arrow
Start command is present, but motor is not running.
For example, start enable is missing.
7 A
0 %
8 mA
8.
3.
30.
15.0Hz
AUTO
MENU
00:00
7 A
0 %
3.
30.
15.0Hz
AUTO
MENU
00:00
mA
44%
Содержание ACS320 series
Страница 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Страница 4: ......
Страница 18: ...18 Safety ...
Страница 28: ...28 Operation principle and hardware description ...
Страница 56: ...56 Electrical installation ...
Страница 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Страница 282: ...282 Actual signals and parameters ...
Страница 358: ...358 Fieldbus control ...
Страница 376: ...376 Fault tracing ...
Страница 382: ...382 Maintenance and hardware diagnostics ...
Страница 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Страница 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Страница 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Страница 412: ...412 Dimension drawings ...
Страница 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...
Страница 442: ...www abb com drives www abb com drivespartners 3AUA0000062599 Rev E EN EFFECTIVE 2016 07 05 Contact us 3AUA0000062599E ...