1-27
[Sysname] local-user user1
[Sysname-user-user1] state block
vlan-assignment-mode
Syntax
vlan-assignment-mode
{
integer
|
string
}
View
ISP domain view
Parameters
integer
: Sets the VLAN assignment mode to integer.
string
: Sets the VLAN assignment mode to string.
Description
Use the
vlan-assignment-mode
command to set the VLAN assignment mode (integer or string) on the
switch.
By default, the VLAN assignment mode is integer, that is, the switch supports its RADIUS
authentication server to assign integer VLAN IDs.
The dynamic VLAN assignment feature enables a switch to dynamically add the ports of successfully
authenticated users to different VLANs according to the attributes assigned by the RADIUS server, so
as to control the network resources that different users can access.
In actual applications, to use this feature together with Guest VLAN, you are recommended to set port
control to port-based mode.
Currently, the switch supports the following two types of assigned VLAN IDs: integer and string.
z
Integer: If the RADIUS authentication server assigns integer type of VLAN IDs, you can set the
VLAN assignment mode to integer on the switch (this is also the default mode on the switch). Then,
upon receiving an integer ID assigned by the RADIUS authentication server, the switch adds the
port to the VLAN whose VLAN ID is equal to the assigned integer ID. If no such a VLAN exists, the
switch first creates a VLAN with the assigned ID, and then adds the port to the newly created
VLAN.
z
String: If the RADIUS authentication server assigns string type of VLAN IDs, you can set the VLAN
assignment mode to string on the switch. Then, upon receiving a string ID assigned by the
RADIUS authentication server, the switch compares the ID with existing VLAN names on the
switch. If it finds a match, it adds the port to the corresponding VLAN. Otherwise, the VLAN
assignment fails and the user fails the authentication.
The switch supports two dynamic VLAN assignment modes to adapt to different authentication servers.
You are recommended to configure the switch according to the dynamic VLAN assignment mode used
by the server.
Table 1-4
lists several commonly used RADIUS servers and their dynamic VLAN assignment modes.
Содержание 5500-EI PWR
Страница 43: ...2 6...
Страница 76: ...1 17...
Страница 228: ...ii stp transmit limit 1 44 vlan mapping modulo 1 45 vlan vpn tunnel 1 46...
Страница 477: ...5 24 Sysname vlan 2 Sysname vlan2 service type multicast...
Страница 503: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23...
Страница 519: ...iii...
Страница 597: ...2 2 security policy server 192 168 0 1 user name format without domain...
Страница 648: ...1 9 Examples Clear static ARP entries Sysname reset arp static...
Страница 663: ...4 3 Sysname resilient arp interface vlan interface 2...
Страница 767: ...1 28 From 12 00 Jan 1 2008 to 12 00 Jun 1 2008...
Страница 1111: ...ii xmodem get 3 18...
Страница 1314: ...A 44 Z...