4. Press 3 to view the allocation of points to a zone:
VIEW ZONES
ZONE? 001
>=ENTER, <=BACK/EXIT
5. Enter the zone to be viewed and press enter. While the report is generated the
following message is displayed:
VIEW ZONE 13
PREPARING REPORT
PLEASE WAIT
<=EXIT
Press escape to cancel the report at any time.
6. The first screen of the report is displayed:
VIEW ZONE 13
LIST OF POINTS HERE
1=BACK,2=NEXT,<=EXIT
7. Press 1 and 2 to move through the list of points in the zone indicated. When the
last page has been displayed The following screen will be displayed:
VIEW ZONE 13
NO MORE POINTS
1=BACK, <=EXIT
8. Press escape to exit the screen.
24.11How To Edit The Allocation Of Points To A Group
1. Enter the engineers menu as described in section 24.
2. Press 1 to select panel set-up. The following screen will be displayed:
1=LOOP SETUP
2=INPUT/OUTPUT SETUP
3=REPEATER SETUP
SELECT 1..2, <=EXIT
3. Press 1, 3, 1. The following screen will be displayed:
1=EDIT POINT GROUPS
2=PRINT POINT GROUPS
3=VIEW POINT GROUPS
SELECT 1..3, <=EXIT