6-2
NUMBER OF RED FLASHES
CAUSE
SOLUTION
1
Power pack high voltage
Reset charger (interrupt AC power for 15
seconds).
2
Power pack low voltage
Reset charger (interrupt AC power for 15
seconds).
3
Charge timeout: caused by power
pack not reaching required voltage.
Charger output was reduced due to
high temperatures.
Check connections.
Operate charger at a lower ambient
temperature.
4
Check power pack: power pack could
not be trickle charged up to minimum
voltage.
Contact CSC.
5
Over-temperature: charger shut down
due to high internal temperature.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15 seconds).
6
Charger internal fault
Reset charger (interrupt AC power for 15
seconds). Contact CSC if fault persists.