Page – 18/75
AFMNA0AA – EPS-BLI HYG – User Manual
6.1 Ampseal
connector
The E-steering controller adopts a 23-poles Ampseal connector. In this manual, each
pin
n
is addressed as A#n or CNA#n.
Figure 6.1-1
A1
Digital input (general purpose redundant).
A2
+5V
+5V supply output.
A3
PBATT
Positive battery connection.
A4
PBATT
Positive battery connection.
A5
PBATT
Positive battery connection.
A6
NBATT
Negative battery connection.
A7
NBATT
Negative battery connection.
A8
NBATT
Negative battery connection.
A9
PCOIL
Positive terminal of the TFD coil (1.3 A max).
A10
NCOIL
Negative terminal of the TFD coil (1.3 A max).
A11
Digital input (general purpose redundant).
A12
SW1
Digital input for the home switch.
A13
GND
Ground (negative reference).
A14
PCOIL2
Safety out (EPS-operative signal).
A15
KEY-IN
Key input (logic supply input).
A16
GND
Ground (negative reference).
A17
CPOC2
2
nd
triangle wave shape PWM.
A18
VCC2
13.5 V 200 mA supply output. Free for future use.
A19
GND
Ground (negative reference).
A20
CPOC1
1
st
triangle wave shape PWM.
A21
+5V
5 V supply output.
A22
CANL1
CAN bus channel LOW (No 120 termination
aboard).
A23
CANH1
CAN bus channel HIGH (No 120 termination
aboard).