AFMNA0AA – EPS-BLI HYG – User Manual
Page – 47/75
28) KEY VOLTAGE MIN
Unit: Volt.
Minimum key voltage sensed by the E-steering controller.
29) CAP VOLTAGE
Unit: Volt.
DC-link capacitors voltage sensed by the E-steering controller.
30) CAP VOLTAGE MAX
Unit: Volt.
Maximum DC-link capacitors voltage sensed by the E-steering controller.
31) CAP VOLTAGE MIN
Unit: Volt.
Minimum DC-link capacitors voltage sensed by the E-steering controller.
32) PMSM TEACH STAT.
Unit: number.
Status of the PMSM auto-teaching.
33) CPU TIME F US
Reserved for internal Zapi technicians.
34) CPU TIME M US
Reserved for internal Zapi technicians.
35) ROTOR ANGLE
Unit: degrees.
Real-time angular position of the rotor.
36) P SENS ERR REG
Unit: number.
Count of the feedback sensor errors.
37) P SENS AGC
Unit: number.
Real-time gain of the feedback sensor.