YORK INTERNATIONAL
150
FORM 100.50-NOM1 (604)
Service
LD09842B
SSP SSN SSAP SSAN TSAO TSC IAQP IAQN
AI
5
AI
5
C
AI
6
AI
6
C
AI
7
AI
7
C
AI
8
AI
8
C
AI
9
AI
9
C
AI
10
AI
10
C
24
VAC
COM
24
VAC
11R
10R
12R
13R
2
2
20
10
12
13
14
7
17
18
19
RETURN
AIR
RH
SENSOR OPTIONAL
OUTSIDE
AIR
TEMP
SENSOR
OUTSIDE
AIR
RH
SENSOR OPTIONAL
RETURN
AIR
TEMP
SENSOR OPTIONAL
BLDG
PRESSURE
TRANSDUCER
DUCT
PRESSURE
TRANSDUCER OPTIONAL
OUT
EXC
COM
COM
OUT
EXC
2 3 4 5
7 8
12
4
3
2
5
2
5
4
3
4
3
2
6ACU
-OPTIONAL
HW/STEAM
VALVE
ACTUATOR
2
5ACU
-OPTIONAL
75%
AMS
DAMPER
ACTUATOR
4ACU
-OPTIONAL
AMS
25%
DAMPER
ACTUATOR
2
5
5
2
5
12R-2
12R-3
12R-4
13R-2
13R-3
13R-4
12R-1
13R-1
2
1LPCO
3
T'STAT
AI
Y1
R
2
16
P
OCC
W2
W
SD
Y2
4
5
C
2
R
TSC
TSAO
COMPRESSOR
SAFETY
CHAIN
STATUS
CIRCUIT
SYSTEM
NO.
1
J29
J30
J22
COMPRESSOR
SAFETY
CHAIN
STATUS
CIRCUIT
SYSTEM
NO.
3
COMPRESSOR
SAFETY
CHAIN
STATUS
CIRCUIT
SYSTEM
NO.
2
3
4
2
24
VAC
24
VAC
SRC2
SRC1
2
3
5
7
10
1
J33
3
4
J34
J35
C/O
RELAY
SUPPLY
FAN
260,
262,
360
EXHAUST
FAN
263,
265,
356
146
145
144
OCC SD SMK
101
102
103
104
105
106
107
108
109
HR
111
121
112
122
113
123
114
124
115
125
116
126
100
C/O RELAY
AO6 AO6C
AO5 AO5C AO4 AO4C
200
2COM
P280
P272
P276
P26
P275
8
7
5
4
2
7
4
7
4
4
4
P134
P136
P139
P23
P25
5
7
8
8 7
5 4 3 2
8 7
5 4 3 2
2
7
J14
PRIMARY
UNIT
CONTROLLER (MOD-DCU)
4 3
7
NEG
PRESSURE
15
VDC
15V(A) 15V(B) 15V(C)
15V(A)
15V(B)
EXC OUT COM
EXC OUT
100
COM
100
200
2COM
COM
ELEMENTARY
DIAGRAM
-YPAL
MOD-C
CLASS
2
CONTROL
70-105
TON
035-13474-102
REV.
B
1T 115V
-24V
CONTROL
TRANSFORMER 100
VA,
CLASS
2
2T 115V
-24V
CONTROL
TRANSFORMER 75
VA,
CLASS
2
SEC
SEC
PRI
PRI
347
346
345
344
343
342
341
340
339
338
337
336
335
334
333
332
331
330
329
328
327
326
325
324
323
322
321
320
319
318
317
316
315
314
313
312
311
310
309
308
307
306
305
304
303
302
301
300
##
LEGEND
CTB1
CONTROL
TERMINAL
BLOCK
FOR
CUSTOMER
CONNECTION
REFER
TO
LINE
#
249,
250
REFER
TO
LI
N
E#2
49
,2
50
2
2
120
5
1
LINE
#
308
LINE
#
308
(100)
CTB2
OPTIONAL
FLEXSYS
CONTROL
TERMINAL
BLOCK
FOR
FIELD
CONNECTION
#
OUTPUT
CONNECTION
FOR
GAS
&
ELECTRIC
HEAT
OPTIONS
1
2LPCO
4
3
3LPCO
5
#
CTB3
RS485
COMM.
BUS
CONTROL
TERMINAL
BLOCK
FOR
FIELD
CONNECTIONS !!!
NOT
FOR
B.A.S.
USE
!!!
129
128
127
9R-2
8R-2
7R-2
100
24VAC
I4
I3
I2
I
P2
P1
I5
I2
I3
I4
P1
P2
I
I2
I3
I4
P1
I
P2
SR1
SR-XM1
SR-XM2
4
2
EVAP
FREEZESTATS
COMP.
SYSTEM
#1
EVAP
FREEZESTATS
COMP.
SYSTEM
#2
EVAP
FREEZESTATS
COMP.
SYSTEM
#3
3STAT
4STAT
7
8
6STAT
5STAT
3
8STAT
7STAT
5
7
8
145
146
121
122
123
124
125
126
112
111
113
114
115
116
150
152
154
COM
100
2
144
145
146
9STAT
AMBIENT THERMOSTAT
155
LINE
#
318
LINE
#
322
LINE
#
326
LINE
#
311
LINE
#
308
LINE
#
306
COM
COM
COM
LINE
#
322
150
152
154
100
100
100
100
155
REFER
TO
LINE
#S
203-211,
217-224,
AND
229-236
FOR
SWITCHED
SIDE
OF
SR1,
SR-XM1
AND
SR-XM2.
J55
J55
J55
J55
J55
J55
144
10STAT
ONLY
USED
ON
UNITS
WITH
EXTENDED
CABINETS
AIR
PROVING
SWITCH
DIRTY
FILTER
SWITCH OPTIONAL
HW
FREEZESTAT
OPTIONAL
SUPPLY
FAN
VFD
BYPASS
STATUS
CIRCUIT.
ONLY
ON
UNITS
EQUIPPED
WITH
A
MANUAL
VFD
BYPASS
KIT
ON
THE
SUPPLY
FAN.
SW2
AND
J49
LOCATED
IN
VFD
BYPASS
KIT
UNDERNEATH
THE
SUPPLY
FAN
VFD.
REFER
TO
LINE
#S
270-273
&
250-251.
10STAT
VFD
2STAT
4PSW
1PSW
2PSW
4PSW
ONLY
USED
ON
UNITS
WITH
EXTENDED
CABINETS
BYPASS
BYPASS
OFF
XOO
BYP
P49
2
100
SW2-3
J28
2 3
3
J49
2
2
J27
J26
2 3
3
J25
P48
LINE
#
312
J48
2
5
120
BI14
BYP
3
4
BI13
BI12
BI11
7
100
24VAC
5
664
664
NOTE,
J34
USED
FOR
HW
VALVE
OR
FOR
MODULATING
GAS
HEAT.
HW
VALVE
SHOWN.