175
YORK INTERNATIONAL
FORM 100.50-NOM1 (604)
8
LD09838
IND
V1
L
RS7
IC4
PSW
TH (W)
LS6
4GV
PS4
PS5
26R-1
IFM4
IND
L
IC5
PSW
TH (W)
V2
27R
LOW
HIGH
FURNACE
CONTROLLER
V2
V1
RS8
27R-1
27R-2
5GV
24V
SEC
16FU
15FU
15FU
230V
PRI
RS10
RS9
V2
V1
32R-1
(R)
TH (W)
IND
L
GND
24 VAC
LS9
LS8
PSW
IC6
6GV
PS6
32R
GND
24 VAC
(R)
GND
24 VAC
(R)
26R
2
2
IGNITOR
IGN
FLAME SENSOR
S1
2
2
3
4
5
IFM5
FLAME SENSOR
IGNITOR
IGN
S1
501
500
501
500
500
501
600
601
600
601
600
601
600A
601A
600B
601B
601
604
605
606
ORN
614
610
611
612
611
612
609
617
608
607
609
610
601
622
619
619
625
627
627
628
629
601
632
632
635
636
637
630
ORN
639
640
641
641
642
644
633
639
623
ORN
IGNITOR
IGN
S1
FLAME SENSOR
325-36145-400
TB1
TB2
400
ELEMENTARY DIAGRAM
YPAL MODULATING GAS
HEAT CONTROLS
70-105 TON
035-13577-002
REV B
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
IFM6
500
501
2
601
600
34R
PSW
TH (W)
645
ORN
FLAME SENSOR
IGNITOR
IND
S1
IGN
GND
24 VAC
L
IC7
(R)
659
654
V2
V1
RS11
650
LS10
RS12
655
656
LS11
651
654
647
647
652
601
657
34R-1
656
PS7
7GV
648
2
2
600C
601C
662
663
660
661
662
663
025-36378-000
MODULATING GAS
VALVE SIGNAL
CONDITIONER
026-40654-000
MODULATING GAS
VALVE
460
461
462
463
464
465
466
467
468
469
470
230 VAC POWER
REFER TO LINES
190-195
OPTIONAL HEAT MODULE REQUIRED FOR UNITS WITH 750 MBH AND
1125 MBH OPTIONS.
325-36145-200
OPTIONAL HEAT MODULE REQUIRED FOR UNITS WITH 1125
MBH OPTIONS.
325-36145-300
MODULE 3 (TOP)
MODULE 2 (BOTTOM)
MODULE 1 (MIDDLE)
LS7
618
1
10
8
7
619
647
617
661
648
5
633
4
607
3
632
2
12
AO6C
668
669
AO6
12
1
10
8
7
4
5
3
2
603
602
24V COM
24VAC
30R
29R
28R
31R
24V
PRI
24V
SEC
1:1 ISOLATION
TRANSFORMER
40VA CLASS 2
SEE DETAIL "A"
607
618
660
602
603
35R
33R
35R-1
33R-1
670
668
669
669
670
610
612
627
TB1
TB2
10T
11T
5
5
5
1K OHM (1/2 WATT)
JUMPER
OPEN CIRCUIT
TB2
TB2
TB2
NO CONNECTION WHEN
EQUIPPED WITH ONLY 1 FURNACE
MODULE.
INSTALL RESISTOR WHEN EQUIPPED
WITH 1 AND 2 FURNACE MODULES.
INSTALL JUMPER WHEN EQUIPPED
WITH 1, 2, AND 3 FURNACE MODULES.
2
3
PS8
AO6
AO6C
664
665
664
665
AO6
AO6C
664
CONTROL HARNESS TO
MICRO/POWER PANEL
CONNECTED TO J34 (LINE #'S 338
- 341)
AIR PROVING SWITCH LOCATED IN
THE SUPPLY FAN SECTION.
DETAIL "A"
FURNACE CONIGURATION SETUP
471
472
473
474
475
476
J59
P59
P58
J58
P57
J57
J60
P60
618
31R-1
674
30R-1
29R-1
28R-1
672
671
673
672
673
671
670
669
#2 START
#1A START
#2 HIGH
#3 HIGH
#1B START
#3 START
#1A HIGH
#1 FAN I/L
0-10V INPUT
0-10V COM
CONFIGURATION
REFERENCE
RUN PERMISSIVE
#1A STATUS
#1A HIGH STATUS
#1B STATUS
#2 STATUS
#3 STATUS
MOD VALVE OUTPUT