143
YORK INTERNATIONAL
FORM 100.50-NOM1 (604)
8
LD09836
OPTIONAL CONDENSER FAN WIRING. CONDENSER FAN VFD REQUIRED ON
CONDENSER FAN NO. 3A WHEN UNIT IS EQUIPPED FOR LOW AMBIENT OPERATION
WITH SYSTEM NO.3.
11M
2VFD
1L2
4FU
REFER TO TRANSFORMER FOR
CONNECTION DETAIL
RETURN FAN
MOTOR #2
15OL
2
X1
GFCI
DUPLEX
OUTLET
10FU
9FU
GND
1PTB
GND
2PTB
ELEMENTARY DIAGRAM - YPAL MOD-B/C
POWER SIDE - 70-105 TON
DUAL POINT POWER w/ RETURN FAN
1L3
1L2
1L1
2L3
2L2
2L1
1L1
GND
035-13472-014
REV. A
TO EARTH
GROUND
1L3
9FU
4FU
V
R
S
T
8FU
8FU
8FU
NOTE: VFD REMOTE MOUNTED
EXTERNAL TO THE CONTROL BOX
OPTIONAL CONDENSER FAN WIRING. CONDENSER FAN VFD REQUIRED ON
CONDENSER FAN NO. 2A WHEN UNIT IS EQUIPPED FOR LOW AMBIENT OPERATION
WITH SYSTEM NO.2.
9M
OPTIONAL CONDENSER FAN WIRING. CONDENSER FAN VFD REQUIRED ON
CONDENSER FAN NO. 1A WHEN UNIT IS EQUIPPED FOR LOW AMBIENT OPERATION
WITH SYSTEM NO.1.
7M
R
S
T
3VFD V
CONDENSER
FAN NO. 1A
1PTB
CONDENSER
FAN NO. 2A
CONDENSER
FAN NO. 3A
V
4VFD
S
T
R
V
5VFD
S
T
R
L3-A
L2-A
L1-A
L3-A
L1-A
L2-A
L3-A
L2-A
L1-A
420
419
418
425
426
424
432
431
430
3T
REFER TO LINE #
200, 201, 203
4T
167
174
177
178
180
179
175
176
171
173
172
169
170
168
153
160
165
166
164
163
162
161
157
158
159
154
156
155
150
152
151
147
149
148
143
145
144
146
141
140
142
112
136
137
139
138
134
133
135
129
130
132
131
126
128
127
119
122
124
125
123
120
121
117
118
116
113
115
114
105
109
111
110
106
107
108
102
103
104
100
101
REFER TO TRANSFORMER FOR
CONNECTION DETAIL
OPTIONAL 120V CONVENIENCE OUTLET KIT
YORK P/N 325-36142-011 (200V UNITS)
YORK P/N 325-36142-012 (230V UNITS)
YORK P/N 325-36142-014 (460V UNITS)
YORK P/N 325-36142-015 (575V UNITS)
1FU
3FU
12M
2FU
3FU
3FU
2FU
2FU
11M
10M
9M
8M
CONDENSER
FAN NO. 1B
CONDENSER
FAN NO. 2A
CONDENSER
FAN NO. 2B
CONDENSER
FAN NO. 3A
CONDENSER
FAN NO. 3B
L3-B
L2-B
L1-B
434
435
433
L1-A
L2-A
L1-B
L2-B
L3-B
L3-A
431
432
430
428
429
427
L1-A
L2-A
L3-B
L2-B
L1-B
L3-A
425
426
424
422
423
421
6M
5M
3M
4M
2M
1FU
1FU
7M
2CB
2OL
CONDENSER
FAN NO. 1A
COMPRESSOR
NO. 3B
COMPRESSOR
NO. 3A
COMPRESSOR
NO. 2A
COMPRESSOR
NO. 2B
COMPRESSOR
NO. 1B
COMPRESSOR
NO. 1A
L1-A
L2-A
L3-A
419
420
418
416
417
415
412
414
413
411
410
405
407
409
408
406
404
403
401
402
400
1CB
1OL
3CB
3OL
4CB
4OL
5CB
5OL
6CB
6OL
1M
SUPPLY FAN
MOTOR
NOTE: VFD REMOTE MOUNTED
EXTERNAL TO THE CONTROL BOX
V
T
1VFD S
R
7FU
7FU
7FU
RETURN FAN
MOTOR #1
14OL
SUPPLY
CIRCUIT #1
(SEE NOTE 1)
SUPPLY
CIRCUIT #2
SUPPLY
CIRCUIT #1
(SEE NOTE 1)
NOTES:
1. ON UNITS EQUIPPED WITH ELECTRIC HEAT, SUPPLY CIRCUIT #1 IS FED FROM THE LOOP FEED POWER BOX MOUNTED TO THE RIGHT OF
THE MICRO/POWER PANEL.