YORK INTERNATIONAL
144
FORM 100.50-NOM1 (604)
Service
LD09837
14OL
2T
115V - 24V CONTROL
TRANSFORMER
75 VA, CLASS 2
5FU
1T
115V - 24V CONTROL
TRANSFORMER
100 VA, CLASS 2
14M
11R-1
6FU
1M AUX
2M AUX
3M AUX
4M AUX
CRANKCASE HEATER
COMPRESSOR 1A
CRANKCASE HEATER
COMPRESSOR 1B
CRANKCASE HEATER
COMPRESSOR 2A
CRANKCASE HEATER
COMPRESSOR 2B
EXHAUST FAN
132, 133, 134
TS
206
205
204
203
202
201
200
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
229
230
231
232
233
234
235
236
237
238
239
X1
2
2
2
2
2
2
2
2
4
5
PRI
SEC
NOTE: THIS CIRCUIT IS OMITTED IF THE UNIT IS EQUIPPED WITH A
EXHAUST FAN VFD.
7
PRI
SEC
PRI
SEC
3T
J41
J41
J42
J42
J43
J43
J44
J44
100
COM
200
2COM
ELEMENTARY DIAGRAM - YPAL MOD-C
CLASS 1 CONTROL
50-65 TON
035-13473-101
REV. -
REFER TO LINE #
124, 125, 126, 127
28
27
18
17
REFER TO
LINE # 300-306
TS
7R
2
2CB
20
19
COMPRESSOR MOTOR PROTECTORS
SYSTEM #1
REFER TO LINE #S 249-256
4CB
29
30
8R
TS
2
240
241
NOTE: THIS CIRCUIT IS USED ON UNITS EQUIPPED WITH AN
ON/OFF SUPPLY FAN. (CV UNITS)
10R-1
3
13OL
5
TS
13M
SUPPLY FAN
120, 121, 122
138, 139, 140
2
10R-1
OPTIONAL SUPPLY FAN VFD
BYPASS KIT
REFER TO LINES
265-268
2
3
J51
2
SFR
OPTIONAL EXHAUST FAN VFD
BYPASS KIT
REFER TO LINES
269-272
EFR
11R-1
2
J53
3
2
J53
J51
NOTE: THIS CIRCUIT IS USED IF UNIT IS EQUIPPED WITH A VARIABLE FREQUENCY DRIVE ON
THE SUPPLY FAN (VAV AND VAV-FLEXSYS UNITS). THE SUPPLY FAN VFD BYPASS KIT IS
OPTIONAL.
NOTE: THIS CIRCUIT IS USED ON UNITS EQUIPPED WITH
ON/OFF POWERED EXHAUST.
NOTE: THIS CIRCUIT AND CAP J53 IS USED IF UNIT IS EQUIPPED WITH A POWERED EXHAUST FAN
DRIVEN BY A VARIABLE FREQUENCY DRIVE. THE EXHAUST FAN VFD BYPASS KIT IS OPTIONAL.
SUPPLY FAN WIRING
REFER TO LINE #S 243-245
OPTIONAL EXHAUST FAN WIRING
REFER TO LINE #S 246-248
2
2
1HPCO
3
T2
M
2
CM1
CM2
P41
COMPRESSOR MOTOR PROTECTOR WIRING FOR
SYSTEM #1. CM1 AND CM2 ARE LOCATED IN
COMPRESSORS 1A AND 1B, RESPECTIVELY. 1HPCO IS
LOCATED ON DISCHARGE LINE BEHIND COMPRESSOR
1A.
17M
16OL
XOO
OOX
BYPASS
VFD
VFD
BYPASS
SW2-1
3
2
J50
CONNECTED TO J51 IN
THE CONTROL BOX
REFER TO LINE #S 244
& 245
OFF
15M
16M
SW2-2
R
2
8
10
SFR
2
SW3-2
SW3-1
10
18M
20M
19M
19OL
8
VFD
BYPASS
XOO
BYPASS
OOX
VFD
OFF
3
CONNECTED TO J53 IN
THE CONTROL BOX
REFER TO LINE #S 247
& 248
EFR
2
2
R
J52
2
271
270
269
245
251
252
250
249
248
247
246
244
243
272
267
268
266
265
COMPRESSOR MOTOR PROTECTORS
SYSTEM #2
REFER TO LINE #S 257-264
OPTIONAL SUPPLY FAN VFD BYPASS KIT. LOCATED IN THE FAN
SECTION UNDER THE SUPPLY FAN VFD.
OPTIONAL EXHAUST FAN VFD BYPASS KIT. LOCATED IN THE
FAN SECTION UNDER THE EXHAUST FAN VFD.
4
P42
3
4
19
2
M
M2
JMP
JMP
M
M2
J41
J42
255
256
254
253
2
2
COMPRESSOR MOTOR PROTECTOR WIRING FOR
SYSTEM #2. CM3 AND CM4 ARE LOCATED IN
COMPRESSORS 2A AND 2B, RESPECTIVELY. 2HPCO IS
LOCATED ON DISCHARGE LINE BEHIND COMPRESSOR
2A.
29
M2
4
J44
J43
264
263
262
261
259
257
258
JMP
JMP
M
M2
M
P44
3
4
3
P43
CM4
CM3
2HPCO
260
3CB
1CB
19B
29B
NOTE: THIS CIRCUIT IS OMITTED IF THE UNIT IS EQUIPPED WITH A
SUPPLY FAN VFD.
5
5
5
M2
M2 M
M2 M
M2 M
2
2
2
T1
T2 T1
2
2
2
2
2
T2 T1
T2 T1
7R-1
GND
GND
3M
TS
TS
4M
9M
TS
TS
10M
1M
TS
2M
TS
TS
7M
8M
TS
GND
GND
2
Q4
Q3
2
Q2
2
2LLSV
J56
4
23
25
23
1M-5
SR-XM1
SR1
8R-1
21
1
20
16
Q
2
2M-5
13
24
22
J40
J39
J56
HGSV
4LLSV
1LLSV
Q4
2
Q3
2
Q2
Q
2
2
15
13
13
14
12
COMPRESSOR 2B
127, 128, 129
SYS 2 LIQUID LINE
SOLENOID VALVE
CONDENSER FAN 2B
151, 152, 153
CONDENSER FAN 2A
148, 149, 150
J56
J56
5
2
2
2
OPT. SYS 1 LIQUID
LINE SOLENOID VALVE
(FLEXSYS UNITS ONLY)
OPT. HOT GAS
SOLENOID VALVE
SYS 1 LIQUID LINE
SOLENOID VALVE
PUMP DOWN
COMPRESSOR 2A
122, 123, 124
2
3
J39
2
2
2
J40
J40
J39
3
2
J56
3
J56
2
2
2
CONDENSER FAN 1B
144, 145, 146
CONDENSER FAN 1A
141, 142, 143
COMPRESSOR 1B
118, 119, 120
COMPRESSOR 1A
113, 114, 115
2
2
2
2
3M-5
30
26
4M-5
J39
4
5LLSV
2
5
J39
GND
OPT. SYS 2 LIQUID
LINE SOLENOID VALVE
(FLEXSYS UNITS ONLY)
J39
227
228
226
225
224
223
COMPRESSOR SYSTEM
PROTECTION CIRCUIT
SYSTEM #1
COMPRESSOR SYSTEM
PROTECTION CIRCUIT
SYSTEM #2