Evaporative
Cooling
Evaporative cooling is nature's way of cooling. When air is moved
over a wet surface, water is evaporated and heat is absorbed.
When
stepping out ofa swimming pool with the wind blowing, evaporative
cooling makes you feel cool, even though the air may be warm.
The human body itself is cooled primarily by the evaporation of
perspiration.
This unit works on the same principle.
Air is drawn across wet
filter pads where the air is cooled
by
evaporation and then circulated
throughout the building.
It is this combination of cooled air and the
movement of air over the skin which makes it feel cool.
Unlike refrigeration systems which recirculate the air,an evaporative
cooler continually brings in fresh air while exhausting old air. You
are completely
replacing the air every 2 to 4 minutes by opening
windows or doors or a combination of both. The air is always fresh,
not stale, laden:with smoke and odors as happens with refrigerated
air conditioning .
Convertible K'tt Nor Shipped With (ookr
Available Upon Request At No Additional
(ost
Read Carefully All Of This Manual
Before Installing The Unit.
Lea Con Cuidado Todo Este Manual Antes
De Instalar La Unidad.
Safety Rules
1. Read these instructions carefully.
2. Unit must be in the Off Position
and Unplugged
from power
receptacle when installing or performing any maintenance.
3. This cooler will run on 120 volt A.C., 60 Hz (cycle) current
only,
4. Motor and pump are grounded and have an automatic thermal
overload switch which will "shutmotor offwhen it overheats.
The
motor will restart automatically
when it cools down.
5. Pump receptacle is for grounded evaporative
cooler pump only_
Do not plug anything else into receptacle.
6. Do Not operate any fan with a damaged cord or plug. Discard fan
or return to an authorized service facility for examination and/or
repair.
7. Do Not run cord under carpeting.
Do Not cover cord with throw
rugs, runners or similar coverings.
Do Not route cord under
furniture or appliances.
Arrange cord away from traffic area and
where it will not be tripped over.
&WARNING:
To reduce the risk offire or electric shock, dn not
use this fan with any ~solid-state fan speed control device."