background image

Troubleshooting

Problem

Possible Cause

Remedy

Problem

Possible Cause

Remedy

Failure to

1.

No electrical power to

I.

Check power

Motor cycles

I.

Low voltage

I.

Check voltage

start or no air

unit

on and ofT

2. Excessive belt tcnsion

2. Adjust belt tension

delivery

Fuse blown

Replace fuse

3. Blower shaft tight or

3. Oil or replace bear-

Circuit breaker

Resel breaker

locked

iogs (Unplug unit)

tripped

4. Bearings dry

4. Oil bearings

Electric cord un-

Plug in cords or

plugged or damaged

replace

if

damaged

Noisy

1.

Bearings dry

1.

Oil bearings

2. Belt too loose or tight

2. Adjust belt tension

2.

Wheel rubbing blower

2.

Inspect and realign

3. Motor overheated

3. Detennine

cause of

housing

(Unplug unit)

overheating

3. Loose parts

3. Tighten loose parts

.

Belt too tight

.

Adjust belt tension

.

Blower bearings dry

Oil blower bearings

Excessive

1.

Inadequate exhaust

1.

Open doors or win~

4. Motor locked

4.

Replace motor

humidity in

dows

house

Inadequate

I.

Insufficient air exhaust

I.

Open windows or

air delivery

doors to increase air

Musty or

I.

Stale or stagnate water

I.

Drain pan and clean

with cooler

flow

unpleasant

in cooler

pads

running

2. Belt too loose

2. Adjust belt tension or

odor

2. Pads mildewed or

2. Replace pads

replace if needed

clogged

3. Pads plugged

J

Replace pads

J

Pads not wetting

3.

Check water distribu-

properly

tion system

Inadequate

I.

Inadequate exhaust in

I.

Open windows or

Trough holes

Clean

cooling

house

doors to increase air

clogged

!low

Pump not working

Replace or clean

2. Pads not wet

2. Check water distribu-

properly

pump (Unplug

tlon system

unit)

Pads plugged

Replace pads

Open spots in pads

Repack pads

Water drain-

I.

Float

31m

not adjusted

I.

Adjust float

Trough holes

Clean trough and

ing from

properly

clogged

unplug holes

cooler

2. Overflowasscmbly

2. Tighten nut and

Pump not working

Replace or clean

leaking

overflow pipe.

properly

pump (Unplug

unit)

Register your product online at

www.championcooler.comli

••dex.phplcooler~lVarranty-registration

Limited Warranty

This walTanty is extended to the original purchaser of an evaporative

cooler installed and used under nonnal conditions.

It does not cover damages incurred

through accident, neglect, or abuse by the owner.

We do not authorizc any person or representative

to assumc for us any other or different liability in con-

nection with this product.

,

Terms And Conditions

Of The Warranty

For Eight Years from date of purchase, we will replace the original base assembly if water leakage should occur due to rust out.

For One Year from date of purchase, we will replace any original component

provided by Champion Cooler which fails due to any defect in material or fac~

tory workmanship

only.

Exclnsions

From The Warranty

We arc not responsible

for replacement

of cooler pads. These arc disposable component,> and should be replaced periodically.

We are not responsible for any

incidental or consequential

damage resulting from any malfunction.

We arc not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor ofa higher horsepower

than what is shown

Oll

the serial plate is used in the unit.

We arc not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.

For limiled warranty to be valid the evaporative

cooler must be maintained

per the Maintenance

Section of this manual.

How To Obtain

Service Under This Warranty

Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfied with the response from the dealer, contact the Customer

Service Department:

5800 Murray Street, Little Rock, Arkansas 72209.

1.800~643.8341.

Email:

[email protected].

This IimUed warranty applies to the original purchaser only.

110496-1

5

Summary of Contents for ESSICK N46W

Page 1: ... 2 to 4 minutes by opening windows or doors or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning Convertible K tt Nor Shipped With ookr Available Upon Request At No Additional ost Read Carefully All Of This Manual Before Installing The Unit Lea Con Cuidado Todo Este Manual Antes De Instalar La Unidad Safety Rules 1 Read...

Page 2: ...ace the two previously removed screws to hold the house leg bracket in place As shown by dotted house leg bracket Refer to the instructions Adjust house legs below for adjusting the house legs Mounting Cooler CA UTION Make sure that the mounting surfacc is strong enough to support thc operating weight of the cooler when in use For operating weight see Specification Table LhCA UTION Never plug in c...

Page 3: ...Place one window fill in panel on each side of grill and into panel retainer strip at bottom of grill Place the other panel retainer strips onto top of neck flange and fill in panels Be sure the panels are snug up against cooler neck Level Cooler Adjust the chains to level the cooler Adjust house legs Pull out house legs so that the rubbcr bumpers rest against house siding F Fig 2 Tighten screw in...

Page 4: ...is a gap tum the metal strip around Remove top _____ screws Illst Do _ _ _ roP Tunnel p I Remove the 9 screws from the sides and bot tom of the tunnel 2 Remove the top 4 mid dle screws of the top pan while holding the tunnel in place Fig 9 Be careful not to drop the tunnel or damage to the electric cords could occur You may need to loosen other screws in the top pan to make it casier to remove the...

Page 5: ...and Pump not working Replace or clean leaking overflow pipe properly pump Unplug unit Register your product online at www championcooler comli dex phplcooler lVarranty registration Limited Warranty This walTanty is extended to the original purchaser of an evaporative cooler installed and used under nonnal conditions It does not cover damages incurred through accident neglect or abuse by the owner ...

Page 6: ... 143 4 WC46 N46W 152 246 341 2 34 1 8 341 8 213 4 143 4 RWC46 RN46W WC50 N50W 155 249 34 1 2 341 8 34 1 8 213 4 143 4 RWC50 RN50W Motor Specifications Especijicaciones Del Motor Model No Motor Part HP Speed Volts Motor Pulley Part Drive Belt Part Mot ell Motar N CV Velocidad Voltios Poleo Del Motor IV 8am a N RWC35 RN35W 110442 1 3 2 115 110271 110226 4L 480 WC37 N37W 110445 1 3 2 115 110271 11021...

Page 7: ...4175 001 Tunnel mnel Cuello Del E dador 322120 001 Blower Housing I Caja De La Rueda 324175 002 Blower Wheel Rlledll 110765 Shan Blower Wheel I Eje De La Rueda 110179 Bearings Blower Wheel Shaft I Cajinetes Del Eje De La Rueda 110351 001 2 Pulley Blower Wheel Polea De La Rueda 110270 Drive Belt Cor ea 110226 Motor Molor 110442 Pulley Motor I Po eaDet Motor 110271 Motor Mount I Monlum Del Molor 320...

Page 8: ...lIantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOLy LOW COOL Ajuste eI intemlplor a la posicion HIGH COOL 0 LOW COOL para poner en marcha el ventilador a una alta 0 baja velocidad junto con Ia bomba Ajuste el interruptor a Ia posicion LOW COOL cuando posible Esta baja velocidad del ventilador pennite que el aire sc queda mas de largo en los filtr...

Page 9: ...equilibrado 1 Tome un pedazo de papel de scda y cortelo a 10 largo en 3 tiTas iguales 2 Ponga en marcha a su enfriador a High Coo 3 Abra una ventana por 10 menos seis pulgadas de ancho en carla sitio que usted dcsee refrescar 4 Tome un pcdazo de papel de seda y pongalo contra la pantalla de la vcntana abierta mas lejos de la apertura del cnfriador Sueltalo al papel de seda Hant una de tres cosas F...

Page 10: ...y ajuste eI flotador para que manlenga este nivel Esto se puede lograr torciendo la varilla para arriba 0 para abajo hg oJ Conecte el tubo de abasteci miento de agua Instale la Have de paso y la valvula de agua en el grifo de agua segun indica la figura 5 Coloque Ia tuerca y la ferula en el tubo y apricle bien la merca para impedir que gotee c1agua Conectar EIAgua Instale el montajc de desagiie Qu...

Page 11: ...o vertical debe soportar la unidad con un soporte o plataforma plana EI metodo de instalacion men cion ado en este manual usando cadenas y las patas no debe ser utilizado Los paneles del rellcno en el kit de instalacion se puede utilizar para aislar la ventana arriba del conducto del cnfriador 5 Con los tornillos quitados previamente de la tapa asc gme eI conducto a la unidad No apricte los tomill...

Page 12: ...omba no funciona Cambiela 0 impiela enmador 2 El montaje de desagiie 2 Apriete la tuerca y el Desconecte la se esta escapando tubo de desague I unidad Registre su producto en linea a www championcooler com index php cooler warranty registration Garantla Limitada La presente garantia se extiende al comprador original de un cnfriador evaporativo instalado y utilizado bajo condiciones nonnales No cub...

Reviews: