![YOKOGAWA TA320 User Manual Download Page 66](http://html.mh-extra.com/html/yokogawa/ta320/ta320_user-manual_911358066.webp)
7-4
IM 704210-01E
Setting readout parameters
• Turning marker display ON/OFF
• ON : Displays the markers.
• OFF : Displays no markers. X1 MARKER, X2 MARKER and MOVEMENT touch keys are
also not displayed.
• Movable range of X1 marker
The X1 marker can move about within the window, as long as it is located on the left of X2
marker. (They can be located in the same position.)
• Movable range of X2 marker
The X2 marker can move about within the window, as long as it is located on the right of X1
marker. (They can be located in the same position.)
• Selecting the marker speed
•
: Causes the markers to move within the window every dot.
•
: Causes the markers to move within the window every 5 dots.
X1 marker
X2 marker
Window
X1: X-axis coordinate of X1 marker
Y1: Y-axis coordinate of X1 marker (frequency of X1)
X2: X-axis coordinate of X2 marker
Y2: Y-axis coordinate of X2 marker (frequency of X2)
N:
• WINDOW calculation area: Total number of samples
present within the window.
• MARKER calculation area: Number of samples present
between X1 and X2 markers.
Note
With a certain center value and span of X-axis, markers may be located in an area which does not actually
exist. For instance, if the center value of X-axis is set to 10 ns and span of X-axis is set to 3.2
µ
s, the
window will contain minus measurement data area. If the markers are located in this area, asterisks “*”
will be displayed instead of the X-axis coordinates.
Setting the calculation function
• Selecting the area
Select WINDOW or MARKER. The item indicated by “N” at the bottom of the screen varies
according to the selected calculation area.
• Setting constant T
Setting range: 10 to 999.9 ns
• Selecting the polarity to be used for display/statistical computation
This menu is displayed only if
is selected for pulse width measurement. Select the desired
polarity from the following to be used for display (histogram, time variation) or statistical
computation.
•
: Displays or performs statistical computation for the positive side only.
•
: Displays or performs statistical computation for the negative side only.
•
: Displays or performs statistical computation for the both positive and negative sides.
However, computation will be performed for the standard deviation and jitter1 only. For
details, refer to 7-7.
7.1 Setting the Histogram Display Function and Reading the Data (Readout)