Operating the XtraDrive Using XtraWare
4.9.7.2.
Deleting a Segment
¾
To delete a segment:
1.
Click any field in the row of the segment that is to be deleted.
2.
Click
Delete
.
The selected segment is deleted.
4.9.7.3.
Editing Values in the Position Setting Table
¾
To edit an entered value:
1.
Click the field that you would like to change.
2.
Enter the new value.
The value is changed, and the table values are automatically updated:
If the value of a Master End position is changed, all subsequent
Master End values are automatically adjusted so as to maintain the
size of the segments as they were before the change. Changing a
Master End value therefore affects only the size of the segment that
the point ends. (The Master Start values are also updated to match
the revised Master End values.)
Changing the value of a Slave End position does not result in
subsequent Slave End values being updated – only the next Slave
Start value is updated.
4.9.8.
Deleting a Profile
¾
To delete a profile:
1.
Select the profile to be deleted from the
Profile List
.
2.
Click
Delete Profile
.
Warning:
Clicking Delete Profile deletes the profile immediately – you will not
be asked for confirmation.