Command Reference
stops.
Notes
1. Movement profiles are according to the Command profile you
set. Make sure that the profile velocity (see section 12.2.1, Profile
Velocity) is greater than that of the master encoder and that the
profile acceleration (see section
12.2.2, Profile Acceleration) is
sufficient to follow it. If the profile velocity is less than that of the
master encoder, the axes can be never synchronized.
2. Speed and acceleration can be changed during motion. The jerk
value used at the beginning of the motion remains in effect as long
as motion mode is Pulse Train Input. Use the STOP_EX command
to change the motion mode.
3. To set deceleration for end of synchronization, use quick stop
deceleration parameters (Pn2A8 and Pn2A9).
Important:
These
parameters also determine the emergency stop
deceleration. Setting too small a value could be dangerous.
Note that this applies only to driver versions up to 2.91. Higher
driver versions decelerate at the profile acceleration.
4. If a filter on command is set (Jerk (Pn2A6) or smooth factor
(Pn216)) the motor will lag after the master encoder according to
the value of the filter.
5. For information on using New_move_enable to enable faster
execution of the MOVE_R command, see section
4.12, Master-
Slave Synchronization.
See Also
Variables: Follower_synchronized, Follower_position_offset
Parameters: Pn200: Determines the reference pulse form.
Pn202, Pn203: The number of received pulses is multiplied by the
electronic gear
(see section
12.1)
ratio you defined.
Pn2A8 and Pn2A9: Quick stop deceleration.
Pn2C4: Synchronizes window for pulse train. Defines the difference
between the Target_position and actual_demand_value where the
Follower_synchronized flag is set to True.
144
XtraWare User Manual
Summary of Contents for XTRAWARE - V3.0
Page 2: ......
Page 4: ......
Page 12: ......
Page 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Page 202: ......
Page 220: ......
Page 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...