Error Messages
Error message
Will servo
turn
Will program
Error
Code
Will motor
stop motion?
from
Description
flow stop?
off?
XtraWare
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
With
Fault
Mngr
Code
W/O
Fault
Mngr
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
Code
83 A.85:
Absolute
Encoder
Over speed
The encoder was
rotating at high
speed
when the power
was turned ON.
Yes Yes Yes Yes Yes
84 A.86:
Encoder
Overheated
The internal
temperature of
the encoder is
too high.
Yes Yes Yes Yes Yes
112 A.91:
Overload
(Warning)
This warning
occurs before
either of the
overload alarms (
A.71 or A.72)
occurs.
If the warning is
ignored and
operation
continues, an
overload alarm
may result.
Yes Yes Yes Yes Yes
113 A.92:
Regenerative
Overload
(Warning)
This warning
occurs before the
regenerative
overload alarm
(A.32) occurs. If
the warning
is ignored and
operation
continues, a
regenerative
overload may
result.
Yes Yes Yes Yes Yes
98 A.A0:
I/O
Board
Disconnected
I/O Board
Disconnected
Yes Yes Yes Yes Yes
85 A.B1:
Reference
Speed
Input Read
Error
The A/D
converter for
reference speed
input is faulty.
Yes Yes Yes Yes Yes
XtraWare User Manual
203
Summary of Contents for XTRAWARE - V3.0
Page 2: ......
Page 4: ......
Page 12: ......
Page 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Page 202: ......
Page 220: ......
Page 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...