Error Messages
198
XtraWare User Manual
Error
Code
Error message
from
XtraWare
Description
Will program
flow stop?
Will motor
stop motion?
Will servo
turn
off?
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
With
Fault
Mngr
Code
W/O
Fault
Mngr
Code
36
ECAM - Too
many profiles
(max 4)
ECAM - Too many
profiles (max 4).
Yes
37 ECAM
Table
already exists
Clear ECAM table
first, using the
ECAM_
TABLE_BEGIN
command.
Yes
38 ECAM
-
Insufficient
number of
points in a
segment,
defined by
ECAM_SEGMEN
T command
Insufficient
number of points
in a segment,
defined by
CAM_SEGMENT
command.
Number of points
is (Delta Master)/
(Master step).
Yes
39
ECAM - No
segments were
downloaded
No segments
were
downloaded.
Yes
40
ECAM - Too
many points in
a segment,
defined by
ECAM_SEGMEN
T command
Too many points
in a segment,
defined
by
CAM_SEGMENT
command.
Number
of points is (Delta
Master)/(Master
step).
Yes
41
ECAM –
Too many
points in
ECAM_POINTS
command (max
4)
In ECAM_POINTS
command, up to
4 points at a time
can be sent.
Yes
42
ECAM - No
ECAM table was
Downloaded
No ECAM table
stored in drive.
Yes
43
ECAM - Slave
overflow
ECAM - Slave
overflow
Yes
44 ECAM
Upload
error
ECAM Upload
error
Yes
Summary of Contents for XTRAWARE - V3.0
Page 2: ......
Page 4: ......
Page 12: ......
Page 79: ...Operating the XtraDrive Using XtraWare Table 14 Sample ECAM Table XtraWare User Manual 69 ...
Page 202: ......
Page 220: ......
Page 258: ...List of Operation Codes 248 XtraWare User Manual versions use STOP_EX ...