Command Reference
5.6.
Serial Communication Commands
The commands described in this section are available only in the serial
communication protocol; they are not available in XtraWare. Detailed
information about the serial communication protocol can be found in
Chapter
6, Serial Interface Protocol.
CLEAR_BUFFER
Table explanation
Syntax
CLEAR_BUFFER <Buffer>
Op. Code
94
Modes
Immediate
Description
Clears either the program buffer or the sequential buffer,
depending on the value of <Buffer>.
It is recommended that this command be used before sending a
program to the drive by serial communication to remove an
existing program from memory. Not doing so can result in
unexpected behavior, such as the program jumping to labels
within the old program.
Syntax
Arguments
<Buffer>
Indicates which buffer is to be cleared:
Buffer Code
Sequential Buffer
0
Program Buffer
1
Serial
1 U
ECAM_POINTS
Table explanation
Syntax
ECAM_POINTS <N> <Slave Delta 1> <Slave Delta 2> <Slave
Delta 3> <Slave Delta 4>
Op. Code
126
Modes
Immediate
Units
Position user units for <Slave Delta>
Description
Specifies the slave position points by setting the delta between
each 2 points in the table.