www.dadehpardazan.ir 88594014-15
10 Appendix
10.2.2 Parameters
10-24
Pn50A
2
Input Signal Selection 1
0000 to FFF1
2100
After restart
Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Input Signal Allocation Mode
Reference
Section
0
Uses the sequence input signal terminals with the factory-set allocations.
1
Changes the sequence input signal allocation for each signal.
Servo ON (/S-ON) Signal Mapping
Signal Polarity: Normal; Servomotor power ON when ON (closed)
Signal Polarity: Reverse; Servomotor power OFF when OFF (open)
Reference
Section
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/P-CON Signal Mapping (P control when ON (closed))
Reference
Section
0 to F
Same as Servo ON Signal (/S-ON) Mapping.
P-OT Signal Mapping (Forward run prohibited when OFF (open))
Reference
Section
0
Forward run allowed when CN1-40 input signal is ON (closed).
1
Forward run allowed when CN1-41 input signal is ON (closed).
2
Forward run allowed when CN1-42 input signal is ON (closed).
3
Forward run allowed when CN1-43 input signal is ON (closed).
4
Forward run allowed when CN1-44 input signal is ON (closed).
5
Forward run allowed when CN1-45 input signal is ON (closed).
6
Forward run allowed when CN1-46 input signal is ON (closed).
7
Forward run prohibited.
8
Forward run allowed.
9
Forward run allowed when CN1-40 input signal is OFF (open).
A
Forward run allowed when CN1-41 input signal is OFF (open).
B
Forward run allowed when CN1-42 input signal is OFF (open).
C
Forward run allowed when CN1-43 input signal is OFF (open).
D
Forward run allowed when CN1-44 input signal is OFF (open).
E
Forward run allowed when CN1-45 input signal is OFF (open).
F
Forward run allowed when CN1-46 input signal is OFF (open).
4th 3rd 2nd 1st
digit digit digit digit
n.
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...