www.dadehpardazan.ir 88594014-15
1 Outline
1-2
1.1
-V Series SERVOPACKs
The
-V Series SERVOPACKs are designed for applications that require frequent high-speed, high-pre-
cision positioning. The SERVOPACK makes the most of machine performance in the shortest time possi-
ble, thus contributing to improving productivity.
1.2
Part Names
This section describes the part names of SGDV SERVOPACK for analog voltage and pulse train reference.
CN5 Analog monitor connector
Used to monitor motor speed, force
reference, and other values through
a special cable (option).
Panel display
Serial number
Used to display SERVOPACK
status, alarm numbers, and other
values when parameters are input.
Connects external regenerative resistors.
Used for control power supply input.
Panel operator keys
Used to set parameters.
Panel operator
Charge indicator
Front cover
CN3 Connector for digital operator
CN1 I/O signal connector
Used for reference input signals and sequence I/O signals.
CN7 Connector for personal computer (USB connector)
Communicates with a personal computer.
Use the connection cable (JZSP-CVS06-02-E).
CN2 Linear scale connector
Connects a serial convertor unit or linear scale.
Ground terminal
Be sure to connect to protect against electric shock.
Main circuit power supply terminals
Used for main circuit power supply input.
Control power supply terminals
Servomotor terminals
Connects the main circuit cable for servomotor.
Connects DC reactor for harmonic suppression.
SERVOPACK model
Regenerative resistor connecting terminals
Input voltage
CN8 Connector for safety function devices
DC reactor terminals for harmonic suppression
CN3
CN7
CN1
CN8
CN2
㧢
With front cover open
Nameplate (Found on side of SERVOPACK.)
Indicates the SERVOPACK model and ratings.
Lights when the main circuit power supply is ON
and stays lit as long as the internal capacitor
remains charged. Therefore, do not touch the
SERVOPACK even after the power supply is
turned OFF if the indicator is lit.
It may result in electric shock.
Refer to
.
.
Refer to
3.6 Connecting Regenerative Resistors
Refer to
3.7.3 Connecting a Reactor for
.
.
Refer to
.
6.1.3 Monitoring Operation during Adjustment
Refer to
.
1.6 SERVOPACK Model Designation
Refer to
Connects a safety function device.
Note: When not using the safety function, use the
SERVOPACK with the safety function’s jumper
connector (JZSP-CVH05-E, provided as an ac-
cessory) inserted.
For the connecting method, refer to
Function Signal (CN8) Names and Functions
For details on how to use the safety function, re-
fer to
.
Connects a digital operator (option, JUSP-OP05A-
1-E) or a personal computer (RS422).
Refer to
-V Series Product Catalog
(No.: KAEP
S800000 42) and
-V Series User’s Manual, Oper-
ation of Digital Operator
(No.: SIEP S800000 55).
47
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...