www.dadehpardazan.ir 88594014-15
5.2 Basic Functions Settings
5-15
5
Op
er
at
io
n
(2) Stopping Method for Servomotor When an Alarm Occurs
There are two types of alarms (Gr.1 and Gr.2) that depend on the stopping method when an alarm occurs.
Select the stopping method for the servomotor when an alarm occurs using Pn001.0 and Pn00B.1.
The stopping method for the servomotor for a Gr.1 alarm is set to Pn001.0.
The stopping method for the servomotor for a Gr.2 alarm is set to Pn00B.1.
Refer to the information on alarm stopping methods
Stopping Method for Servomotor for Gr.1 Alarms
The stopping method of the servomotor when a Gr.1 alarm occurs is the same as that in
for Servomotor after /S-ON Signal is Turned OFF
Stopping Method for Servomotor for Gr.2 Alarms
Zero-speed stopping: The speed reference is set to 0 to stop quickly.
Note: The setting of Pn00B.1 is effective for position control and speed control. Pn00B.1 will be ignored for force control
and only the setting of Pn001.0 will be valid.
Parameter
Stop Mode
Mode After Stop-
ping
When Enabled
Classification
Pn001
n.
0
[Factory setting]
DB
DB
After restart
Setup
n.
1
Coast
n.
2
Coast
Coast
Parameter
Stop Mode
Mode After
Stopping
When
Enabled
Classifica-
tion
Pn00B
Pn001
n.
0
[Factory setting]
n.
0
[Factory setting]
Zero-speed stop-
ping*
DB
After
restart
Setup
n.
1
Coast
n.
2
n.
1
n.
0
[Factory setting]
DB
DB
n.
1
Coast
n.
2
Coast
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...