www.dadehpardazan.ir 88594014-15
6 Adjustments
6.1.4 Safety Precautions on Adjustment of Servo Gains
6-10
Related Parameter
Related Alarm
(4) Vibration Detection Function
Set the vibration detection function to an appropriate value with the vibration detection level initialization
(Fn01B). For details on how to set the vibration detection function, refer to
7.16 Vibration Detection Level
.
(5) Excessive Position Error Alarm Level at Servo ON
If position errors remain in the error counter when turning ON the servomotor power, the servomotor will
move and this movement will clear the counter of all position errors. Because the servomotor will move sud-
denly and unexpectedly, safety precautions are required. To prevent the servomotor from moving suddenly,
select the appropriate level for the excessive position error alarm level at servo ON (Pn526) to restrict opera-
tion of the servomotor.
Related Parameters
Related Alarms
When an alarm occurs, refer to
and take the corrective actions.
Pn520
Excessive Position Error Alarm Level
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 1073741823
1 reference unit
5242880
Immediately
Setup
Alarm Dis-
play
Alarm Name
Meaning
A.d00
Position Error Overflow
Position errors exceeded parameter Pn520.
Position
Pn526
Excessive Position Error Alarm Level at Servo ON
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 1073741823
1 reference unit
5242880
Immediately
Setup
Position
Pn528
Excessive Position Error Warning Level at Servo ON
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
10 to 100
1%
100
Immediately
Setup
Pn584
Speed Limit Level at Servo ON
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 10000
1 mm/s
10000
Immediately
Setup
Position
Position
Alarm Dis-
play
Alarm Name
Meaning
A.d01
Position Error Overflow
Alarm at Servo ON
This alarm occurs if the servomotor power is turned ON when the position
error is greater than the set value of Pn526 while the servomotor power is
OFF.
A.d02
Position Error Overflow
Alarm by Speed Limit at
Servo ON
When the position errors remain in the error counter, Pn584 limits the speed
if the servomotor power is turned ON. If Pn584 limits the speed in such a
state, this alarm occurs when reference pulses are input and the number of
position errors exceeds the value set for the excessive position error alarm
level (Pn520).
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...