www.dadehpardazan.ir 88594014-15
4 Trial Operation
4-10
5
Perform trial operation with the servomotor connected to the machine, following
each section in
4.3 Trial Operation for Servomotor without Load from Host Refer-
Check that the trial operation is completed with as the trial operation for servomotor
without load. Also check the settings for machine such as reference unit.
4.3 Trial Operation for
Servomotor without Load
from Host Reference
6
Check the settings of parameters for control method used set in step 2 again.
Check that the servomotor moves matching the machine operating specifications.
7
Adjust the servo gain and improve the servomotor response characteristics, if neces-
sary.
8
Write the parameters set for maintenance in
10.4 Parameter Recording Table
Then the trial operation with the servomotor connected to the machine is completed.
Note: If the optional digital operator is used, parameters can be saved. S,
which is a tool for supporting the servo drive, can then manage the saved
parameters in files.
10.4 Parameter Record-
ing Table
(cont’d)
Step
Operation
Reference
Note: The servomotor will not be broken in completely during the trial operation.
Therefore, let the system run for a sufficient amount of additional time to
ensure that it is properly broken in.
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...