www.dadehpardazan.ir 88594014-15
7.9 Gain Adjustment of Analog Monitor Output (Fn00D)
7-15
7
Utili
ty Fu
ncti
ons (Fn
)
7.9
Gain Adjustment of Analog Monitor Output (Fn00D)
This function is used to manually adjust the gains for the analog monitor outputs (force reference monitor out-
put and motor moving speed monitor output). The gain values are factory-set before shipping. Therefore, the
user need not usually use this function.
(1) Adjustment Example
An example of gain adjustment to the motor moving speed monitor is shown below.
The gain adjustment range is made with a 100% output set as a center value (adjustment range: 50% to 150%).
The following is a setting example.
<Setting the Set Value to
125>
100% + (
125
0.4) = 50%
Therefore, the monitor output voltage is 0.5 time as high.
<Setting the Set Value to 125>
100% + (125
0.4) =150%
Therefore, the monitor output voltage is 1.5 times as high.
Note:
The adjustment value will not be initialized when parameter settings are initialized using Fn005.
(2) Preparation
The following condition must be met to adjust the gain of the analog monitor output.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
Item
Specifications
Gain-adjustment Range
100
50%
Adjustment Unit
0.4%/LSB
Analog monitor
output voltage
Gain adjustment
Motor speed
1 [V]
1000 [mm/s]
Linear
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...