www.dadehpardazan.ir 88594014-15
6 Adjustments
6.8.3 Current Control Mode Selection Function
6-62
6.8.3
Current Control Mode Selection Function
This function reduces high-frequency noises while the servomotor is being stopped. This function is enabled
by default and set to be effective under different application conditions. Set Pn009.1 = 1 to use this function.
This function can be used with the following SERVOPACKs.
6.8.4
Current Gain Level Setting
This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK
according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level
(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise
will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current
gain level within the allowable range at which SERVOPACK response characteristics can be secured. This
function is always disabled in force control (Pn000.1 = 2).
6.8.5
Speed Detection Method Selection
This function can ensure smooth movement of the servomotor while the servomotor is running. Set the value
of Pn009.2 to 1 and select speed detection 2 to smooth the movement of the servomotor while the servomotor
is running.
When the scale pitch of the linear scale is large, the noise level of the running servomotor can be reduced.
Input Voltage
SERVOPACK Model SGDV-
200 V
120A, 180A, 200A, 330A, 550A
400 V
3R5D, 5R4D, 8R4D, 120D, 170D, 260D
Parameter
Meaning
When Enabled
Classification
Pn009
n.
0
Selects the current control mode 1.
After restart
Tuning
n.
1
[Factory setting]
Selects the current control mode 2 (low noise).
• If current control mode 2 is selected, the load ratio may increase while the servomotor
is being stopped.
Pn13D
Current Gain Level
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
100 to 2000
1%
2000
Immediately
Tuning
• If the parameter setting of the current gain level is changed, the responses character-
istics of the speed loop will also change. The SERVOPACK must, therefore, be read-
justed again.
Speed
Position
Parameter
Meaning
When Enabled
Classification
Pn009
n.
0
[Factory setting]
Selects speed detection 1.
After restart
Tuning
n.
1
Selects speed detection 2.
• If the speed detection method is changed, the response characteristics of the speed
loop will change and the SERVOPACK must be readjusted again.
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...