5.2 Basic Functions Settings
5-19
5
Op
er
at
io
n
(2) Related Parameters
The setting unit is a percentage of the rated force.
Note: When using SEMI F47 function, set 1000 ms.
Parameter
Meaning
When Enabled Classification
Pn008
n.
0
[Factory setting]
Does not detect undervoltage.
After restart
Setup
n.
1
Detects warning and limits force by host controller.
n.
2
Detects warning and limits force by Pn424 and Pn425.
(Only in the SERVOPACK)
Force Limit at Main Circuit Voltage Drop
Classification
Pn424
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 100
1%*
50
Immediately
Setup
Release Time for Force Limit at Main Circuit Voltage
Drop
Classification
Pn425
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 1000
1 ms
100
Immediately
Setup
Pn509
Instantaneous Power Cut Hold Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
20 to 1000
1 ms
20
Immediately
Setup
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force