www.dadehpardazan.ir 88594014-15
3.3 I/O Signal Allocations
3-23
3
Wi
ri
ng and
C
onne
ctio
n
3.3
I/O Signal Allocations
This section describes the I/O signal allocations.
3.3.1
Input Signal Allocations
In most cases, input signals can be used at the factory settings. Input signals can also be allocated as required.
(1) Using Factory Settings
Items in cells with bold lines in the following table are the factory-set signal allocations.
If the control method is changed in Pn000.1, the signals will function as required for the control method.
The factory-set signal allocations will remain unchanged.
<Example>
When the control method is set to internal set speed control with a contact reference, i.e., when Pn000.1 is set
to 3, signal /P-CON (CN1-41) will function as /SPD-D, signal /P-CL (CN1-45) as /SPD-A, and signal /N-CL
(CN1-46) as /SPD-B.
Pn000.1
Setting
Control Method Selection
CN1 Pin No.
40
41
42
43
44
45
46
0
Speed control
/S-ON
Uses as
/P-CON
P-OT
N-OT
/ALM-
RST
/P-CL
/N-CL
1
Position control
2
Force control
3
Internal set speed control
Uses as
/SPD-D
Uses as
/SPD-A
Uses as
/SPD-B
4
Internal set speed control
Speed control
5
Internal set speed control
Position control
6
Internal set speed control
Force control
7
Position control
Speed control
Uses as
/C-SEL
Uses as
/P-CL
Uses as
/N-CL
8
Position control
Force control
9
Force control
Speed control
A
Speed control
Speed control with zero clamp function
Uses as
/ZCLAMP
B
Position control
Position control with reference pulse
inhibit function
Uses as
/INHIBIT
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...