7.8 Monitoring Machine Operation
7.8.3 Realtime Tracing
7
Cr
eating U
s
er Pr
ogram
s
7-97
•
Details
Use this setting to specify a register for triggering the trace.
No.
Item
Description
Details
Use this option to specify the register (Bit, Word, Float, or Long) to use to trigger
the trace. You can freely create the desired combination of conditions to start
and stop the trace.
Initiate
Enter any register and value to start the trace.
If the initiate trigger is not specified, tracing will start at the same time as the
sampling.
Condition
Select from the following operators:
Operator
Trigger
>
<
=
<>
>=
<=
A trigger occurs when the register value is greater than the compari-
son value.
A trigger occurs when the register value is less than the comparison
value.
A trigger occurs when the register value is equal to the comparison
value.
A trigger occurs when the register value is not equal to the compari-
son value.
A trigger occurs when the register value is greater than or equal to
the comparison value.
A trigger occurs when the register value is less than or equal to the
comparison value.
Terminate
Enter any register and value to start the trace.
If a terminate trigger is not specified, tracing will continue until the sampling
stops.
No. of Delays
Set the number of samplings to execute after the terminate trigger condition has
been met and before the trace is stopped.