4.3 Self Configuration
4.3.2 Confirming Definition Information Updated by Self Configuration
4-30
Module Configuration Definition Tab Page Details
The following table describes the items that are displayed in the Module Configuration Defini-
tion Tab Page.
*
Set I/O registers so that the same registers are not used by more than one Function Module.
No.
Item
Display/Setting Item
Setting Range/Settings
Editing
Module
Displays the Module that is set for the
slot.
Any module
Possi-
ble
Function Module/Slave
Displays the Function Modules and
slaves that are used by the Module.
Any Function Module or
slave
Possi-
ble
Status
In Online Mode, displays the status of
the Function Modules and the com-
munications status of MECHA-
TROLINK slave devices.
Refer to the following sec-
tion.
Not
possi-
ble
Circuit No./
Axis Address
Start
Displays the first circuit number that is
assigned to the Module.
Circuit No. 1 to 16
Possi-
ble
Occu-
pied cir-
cuits
Displays the number of circuits that
are assigned to the Module.
1 and 2
Possi-
ble
Motion Register
Displays the first and last register
numbers of the motion parameters.
The parameter is automati-
cally set based on the circuit
numbers.
Not
possi-
ble
Register
(Input/Out-
put)
Disabled
Used to disable inputs or outputs by
selecting the check boxes.
Selected or not selected
Possi-
ble
Start -
End
Displays the range of registers that is
used as an I/O area by the Function
Module. For the SVC4, the first and
last registers of the I/O Modules that
are connected to MECHATROLINK
are displayed.
Start: 0000h to 7FFFh,
End: 10000h to 17FFFh,
800h words max.*
Possi-
ble
Size
Displays the number of words in the
I/O area.
The size depends on the
function of the Module.
Possi-
ble
Scan
Displays the scan in which the I/O
service is performed for the I/O
device.
High/Low
Possi-
ble
Comment
Displays the user comment.
You can enter up to 16 char-
acters for a Function Mod-
ule. You can enter up to 32
characters for a MECHA-
TROLINK slave.
Possi-
ble