12.7 IO16 Function Module
12.7.2 Setting Procedure for the IO16 Function Module
12-50
2.
Double-click the
IO16
Cell.
The Detail - [Local I/O] Dialog Box will be displayed.
3.
Make the settings for discrete inputs, discrete outputs, and interrupt inputs.
No.
Item
Description
D
Click to enable or disable each item.
The register length is one word and cannot be changed. Therefore, each setting
applies to all 16 inputs or 16 outputs.
REG
Displays the register addresses that are assigned to the inputs and outputs. The regis-
ter addresses cannot be changed.
Word
Displays the data size in number of words of the register. The number of words cannot
be changed.
SCAN
Select high-speed, low-speed, or NA (not specified) as the scan in which to process
the inputs and outputs.
Current Value
If the SERVOPACK is online, the current values of the registers are displayed as binary
numbers. The current values are not displayed when the SERVOPACK is offline.
You can change the current values of the discrete outputs to set the outputs to exter-
nal devices. The settings are immediately saved in the register when the settings are
confirmed.
Other current values cannot be changed.
HEX
If the SERVOPACK is online, the current values of the registers are displayed as hexa-
decimal numbers.
The current values are not displayed when the SERVOPACK is offline.
: Enable
: Di
s
able