3.5 Wiring the Power Supply to the SERVOPACK
3.5.4 Power Supply Wiring Diagrams
3
Wiring and Connection
s
3-29
3.5.4
Power Supply Wiring Diagrams
Using Only One SERVOPACK
•
Wiring Example for Three-Phase, 200-VAC Power Supply Input
The following diagram shows the wiring to stop both Servomotors when there is an alarm for
one axis.
WARNING
Even after you turn OFF the power supply, a high residual voltage may still remain in the
SERVOPACK. To prevent electric shock, do not touch the power supply terminals after you
turn OFF the power. When the voltage is discharged, the CHARGE indicator will turn OFF.
Make sure the CHARGE indicator is OFF before you start wiring or inspection work.
2KM
L1
0 V
1Ry
ALM_A+
19
22
1D
B2
B
3
L2
CN1
1KM
L1C
L
3
L2C
1QF
R
S
T
1FLT
+24 V
1
2
3S
A
B1/
1QF: Molded-ca
s
e circuit breaker
1FLT: Noi
s
e Filter
1KM: Magnetic Contactor (for control power
s
upply)
2KM: Magnetic Contactor (for main circuit power
s
upply)
1Ry: Relay
1PL: Indicator lamp
1
S
A:
S
urge Ab
s
orber
2
S
A:
S
urge Ab
s
orber
3S
A:
S
urge Ab
s
orber
1D: Flywheel diode
1PL
1KM
2KM
1
S
A
S
ervo power
ON
S
ervo power
OFF
2
S
A
1KM
1Ry
1KM
ALM_B-
20
ALM_A-
21
ALM_B+
1Ry
(For
s
ervo alarm di
s
play)
S