2.1 Installation Precautions
2-2
2.1
Installation Precautions
Refer to the following section for the ambient installation conditions.
Installation Near Sources of Heat
Implement measures to prevent temperature increases caused by radiant or convection heat
from heat sources so that the temperature around the SERVOPACK meets the surrounding air
conditions.
Installation Near Sources of Vibration
Install a vibration absorber on the installation surface of the SERVOPACK so that the SERVO-
PACK will not be subjected to vibration.
Installation Near Devices That Generate Strong Magnetic Fields
Do not install the SERVOPACK in a location with a magnetic density of 0.01 teslas (100
gausses) or greater.
Other Precautions
Do not install the SERVOPACK in a location subject to high temperatures, high humidity, water
drops, cutting oil, excessive dust, excessive dirt, excessive iron powder, corrosive gasses, or
radioactivity.