10.2 List of Parameters
10-31
10
Ap
pend
ix
Pn515
2
Input Signal Selection 6
0000 to FFFF
−
8888
After restart
Setup
−
Pn517
2
Reserved (Do not change.)
–
–
0000
–
–
–
Pn51B
4
Reserved (Do not change.)
–
–
1000
–
–
–
Pn51E
2
Excessive Position Error Warn-
ing Level
10 to 100
1%
100
Immediately
Setup
9.2.1
Pn520
4
Excessive Position Error Alarm
Level
1 to
1073741823
1
reference
unit
5242880
Immediately
Setup
6.1.4
9.1.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled Classifi-
cation
Reference
Section
Reserved (Do not change.)
Reference Pulse Input Multiplication Switching Input Signal Mapping (/PSEL)
Reference
Section
0
Active when CN1-40 input signal is ON (closed).
5.4.3
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
Dynamic Brake Answer Signal Input Signal Mapping (/DBANS)
Reference
Section
0
Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while
the DB is applied.
3.9.4
1
Detects DB contactor errors when the input signal of CN1-41 is ON (closed) while the DB is applied.
2
Detects DB contactor errors when the input signal of CN1-42 is ON (closed) while the DB is applied.
3
Detects DB contactor errors when the input signal of CN1-43 is ON (closed) while the DB is applied.
4
Detects DB contactor errors when the input signal of CN1-44 is ON (closed) while the DB is applied.
5
Detects DB contactor errors when the input signal of CN1-45 is ON (closed) while the DB is applied.
6
Detects DB contactor errors when the input signal of CN1-46 is ON (closed) while the DB is applied.
7, 8
Disables DB contactor error detection of DB answer signal.
9
Detects DB contactor errors when the input signal of CN1-40 is OFF (open) while the DB is applied.
A
Detects DB contactor errors when the input signal of CN1-41 is OFF (open) while the DB is applied.
B
Detects DB contactor errors when the input signal of CN1-42 is OFF (open) while the DB is applied.
C
Detects DB contactor errors when the input signal of CN1-43 is OFF (open) while the DB is applied.
D
Detects DB contactor errors when the input signal of CN1-44 is OFF (open) while the DB is applied.
E
Detects DB contactor errors when the input signal of CN1-45 is OFF (open) while the DB is applied.
F
Detects DB contactor errors when the input signal of CN1-46 is OFF (open) while the DB is applied.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.