5 Operation
5.7.1 Switching Internal Set Speed Control (Pn000.1 = 4, 5, or 6)
5-52
5.7
Combination of Control Methods
The multi-winding drive unit can switch between a combination of two control methods. Select the control
method with Pn000.1.
5.7.1
Switching Internal Set Speed Control (Pn000.1 = 4, 5, or 6)
Conditions for switching internal set speed control are as shown below.
(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)
The control method and internal set speed can be switched using /P-CL and /N-CL signals.
It is possible to switch from speed control, position control, or torque control to the internal set speed control
even while the servomotor is rotating.
Parameter
Combination of Control Methods
When Enabled Classification
Pn000
n.
4
Internal Set Speed Control
↔
Speed Control
After restart
Setup
n.
5
Internal Set Speed Control
↔
Position Control
n.
6
Internal Set Speed Control
↔
Torque Control
n.
7
Position Control
↔
Speed Control
n.
8
Position Control
↔
Torque Control
n.
9
Torque Control
↔
Speed Control
n.
A
Speed Control
↔
Speed Control with Zero Clamp Func-
tion
n.
B
Position Control
↔
Position Control with Reference
Pulse Inhibit Function
Input Signal
Pn000.1 Settings and Operations
/P-CON (CN1-41)
/P-CL (CN1-45)
/N-CL (CN1-46)
n.
4
n.
5
n.
6
OFF
OFF
OFF
Speed control
Position control
Torque control
OFF
ON
Forward rotation at internal set speed 1 set in Pn301.
ON
ON
Forward rotation at internal set speed 2 set in Pn302.
ON
OFF
Forward rotation at internal set speed 3 set in Pn303.
ON
OFF
OFF
Speed control
Position control
Torque control
OFF
ON
Reverse rotation at internal set speed 1 set in Pn301.
ON
ON
Reverse rotation at internal set speed 2 set in Pn302.
ON
OFF
Reverse rotation at internal set speed 3 set in Pn303.