Setup
236
Reference Manual
◆
Error messages
The SYSTEM indicators will remain lit/blinking cyclically as follows until the problem has been
resolved.
If service is necessary, please contact the Yamaha service center listed in the CL5/CL3/CL1
Owner's Manual.
◆
Warning messages
The indicators will remain lit/blinking cyclically until the problem has been resolved.
If the green [SYNC] indicator is not lit, the device's word clock is not defined.
[SYNC] indicators
Meaning
Possible solution
Blinking
The word clock is not set
correctly.
Set the word clock master and the
sampling frequency correctly on
the CL5/CL3/CL1-native device or
in Dante Controller.
Flash x2
Dante Network circuit is
broken.
Make sure that the Ethernet
cables are not removed or short-
circuited.
Flash x3
Dante Network is connected
incorrectly. Other Dante
devices cannot be found.
Make sure that the Ethernet
cables are connected correctly.
If the green indicator is blinking, the unit is operating as the word clock master.
If the green indicator lights, the unit is operating as a word clock slave and synching to the
word clock.
[SYNC] indicators
Meaning
Possible solution
Lit or
Lit
blinking
A non-GbE-compatible device
is connected.
If audio is transmitted over the
Dante network, use a GbE-
compatible device.
Lit or
Blinkin
g blinking
The SECONDARY connector
has taken over
communications during
redundant network operation.
Check the circuit connected to the
PRIMARY connector.
[SYSTEM] indicators
Meaning
Possible solution
Flash x2
An internal error has occurred.
The device has failed. Contact
your Yamaha dealer for repair.
Flash x3
The MAC address setting has
been corrupted and no
communication can occur via
Dante.
Lit
Flash x3
The internal memory has
been corrupted.
If the problem persists after
setting START UP MODE back to
RESUME and turning the power
on again, consult your Yamaha
dealer.
Lit
UNIT ID is not unique.
Set a unique UNIT ID number for
the Dante network.
flash
The DIP switches are not set
correctly.
Check the DIP switch settings,
and set them correctly.
Lit
Blinking
Dante flow number limit was
exceeded.
Examine the Dante network
routing.
USO