129
Reference Manual
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
Inserting a GEQ in a channel
This section explains how to insert a GEQ into the selected channel for use.
STEP
1.
Refer to steps 1-8 in “
) to mount a GEQ in a rack
and set its input source and output destination.
2.
In the GEQ field, press the rack container in which you mounted the GEQ.
3.
If you're using a stereo source, press the RACK LINK button to link the two GEQ
units.
4.
Press the GEQ ON/OFF button to turn the GEQ on.
NOTE
• If you are using a stereo source, you can mount a Flex15GEQ, or mount two 31BandGEQ units
in adjacent odd-numbered/even-numbered racks. This will let you link the two GEQ units in a later
step.
• You can view the input and output levels of the GEQ in the rack in the GEQ field.
• For details on GEQ operations, refer to the following section “
or “
GEQ EDIT window
NOTE
The windows for the 31BandGEQ and the Flex15GEQ are nearly identical. However, the
Flex15GEQ individually displays two GEQ units (A and B) mounted in a single rack.
2
3
4 5 6
1
2
INPUT button
Press this button to open the CH SELECT window, in which you can select the input
source of the rack. The operating procedure is the same as for the INPUT button in the
GEQ field.
3
OUTPUT button
Press this button to open the CH SELECT window, in which you can select the output
destination of the rack. The operating procedure is the same as for the OUTPUT button
in the GEQ field.
4
RACK LINK button
Press this button to open the RACK LINK window, in which you can link adjacent GEQ units.
In the case of a 31bandGEQ, the GEQ units in adjacent odd-numbered/even-numbered
racks will be linked. In the case of a Flex15GEQ, the GEQ(A) and GEQ(B) within the same
rack will be linked.
•
GEQ x
y button ( “x” and “y” are the rack number, or the rack number and
alphabetical character A or B)
The parameters of “x” will be copied to
“
y,” and then linked.
•
GEQ y x button
The parameters of
“
y” will be copied to
“
x,” and then linked.
•
RESET BOTH button
The parameters of both will be initialized, and then linked.
•
CANCEL button
Cancels the link and closes the window.
NOTE
The RACK LINK button is shown only if linking is possible. When you link
GEQ units, a symbol will appear in the GEQ field to indicate the linked status.
5
FLAT button
Returns all bands of the currently-selected GEQ to 0 dB.
6
GEQ ON/OFF button
Switches the currently-selected GEQ on or off.
1
Rack select tabs
Switch among GEQ 1-8 or among GEQ 9-16. For a rack in which a Flex15GEQ is
mounted, the tabs will be split as xA and xB (x is the rack number).
USO
RESTRITO
Summary of Contents for CL5
Page 257: ...Data List USO RESTRITO ...