![background image](http://html.mh-extra.com/html/xerox/phaser-2135/phaser-2135_advanced-features-and-troubleshooting-manual_885471102.webp)
Advanced Features and Troubleshooting Manual
89
Troubleshooting
J
n
-Toner Empty
[J9-Yellow Toner Empty]
[J10-Magenta Toner Empty]
[J11-Cyan Toner Empty]
[J12-Black Toner Empty]
Fault
The toner cartridge has reached its end of life.
Install a new toner cartridge.
Load
Size, Type, Tray #
Fault
The specified paper size and type requested by the
print job is not available in the specified tray.
Load the specified paper or press
Enter
to print
from the tray regardless of what paper size and
type is loaded.
T1-Fuser Upper Error
Fault
An error in the upper fuser Thermistor was
discovered. Verify that the clearances around the
printer are consistent with the recommendations
in the
User safety summary
. Turn off the printer,
wait 15 seconds, then turn on the printer. If the
problem persists, install a new fuser. For further
assistance, visit the support links at:
www.xerox.com/officeprinting
/
infoSMART
.
T2-Fuser Lower Error
Fault
An error in the lower fuser Thermistor was
discovered. Turn off the printer, wait 15 seconds,
then turn on the printer. If the problem persists,
install a new fuser. For further assistance, visit the
support links at:
www.xerox.com/officeprinting
/
infoSMART
.
T29-Temp Sensor Error
Fault
The temperature sensor is either not
communicating or reporting invalid data. To reset
the sensor, open and close the Top Cover. If the
problem persists, check the support links at:
www.xerox.com/officeprinting
/
infoSMART
.
T30-RH Sensor Error
Fault
The relative humidity sensor is either not
communicating or reporting invalid data. Turn off
the printer, wait 15 seconds, then turn on the
printer. If the problem persists, check the support
links at:
www.xerox.com/officeprinting
/
infoSMART
.
T31-Roller Over Temp
Fault
The fuser temperature sensor is reporting a
temperature error. Turn off the printer, wait 15
seconds, then turn on the printer. If the problem
persists, install a new fuser. For further assistance,
visit the support links at:
www.xerox.com/officeprinting
/
infoSMART
.
T32-LED Over Temperature
Fault
One of the LED bars is reporting a temperature
error. Turn off the printer, wait 15 seconds, then
turn on the printer. If the problem persists, check
the support links at:
www.xerox.com/officeprinting
/
infoSMART
.
Printer Management Status Messages (cont'd.)