![background image](http://html2.mh-extra.com/html/xerox/cipress-325/cipress-325_customer-help-information_3806560108.webp)
1. Check the SP temperature values on the front of the Thermal Controller.
Action
Result
Contact Xerox for assistance.
The SP temperature values
(the numbers displayed on
the bottom) are not set as
follows:
• Zone 1: 51.5 degrees
celsius
• Zone 2: 25 degrees
celsius
• Zone 3: 53 degrees
celsius
Continue with the next step.
All SP temperature values
are set correctly.
2. Check the PV temperatures on the front of the Thermal Controller.
Action
Result
The PV temperatures (the
numbers displayed on the
top) are not within the
following temperature
ranges:
1.
Wait 30 minutes from the time the Thermal Controller
is initially powered on to allow the three temperature
zones to stabilize.
2.
Recheck PV temperatures.
• Zone 1: Between 49 and
54 degrees celsius
• One or more of the PV temperatures is outside of the given
temperature range. Contact Xerox for assistance.
• Zone 2: Between 22.5
and 27.5 degrees celsius
• If all PV temperatures are now within the given
temperature range continue with the next step.
• Zone 3: 50.5 and 55.5
degrees celsius
Continue with the next step.
All PV temperatures are
within the given
temperature range.
Xerox
®
CiPress™ 325 / 500 Production Inkjet System
5-6
Customer Help Information
Problem Solving
Summary of Contents for CiPress 325
Page 16: ...Xerox CiPress 325 500 Production Inkjet System 1 8 Customer Help Information CiPress System...
Page 28: ...Xerox CiPress 325 500 Production Inkjet System 2 12 Customer Help Information Power Management...
Page 30: ...Xerox CiPress 325 500 Production Inkjet System 3 2 Customer Help Information Web Setup...
Page 191: ......
Page 192: ......