DSC AND SCS DATA STREAM COMMANDS
Transparent (TRN)
35nn
Indicates the start of a transparent data stream. Since you define
the data within a transparent stream, the printer does not scan
the SCS data for control codes. A hyphen is substituted,
however, for all codes below X'40.'
35
Control sequence prefix of a Transparent
command
nn
Number of bytes following this command not to
be checked for printed data stream commands
Valid values for nn range from 0—FF.
Remember
Data is sent according to Function Selection via Line (FSL) Y37—
IBM Printer Emulation Select command. Refer to the “Y37—IBM
Printer Emulation Select” section in the “Function Selection via
Line (FSL) commands” chapter for more information on this FSL
command.
Vertical Channel Select (VCS)
04vv
Allows the movement of the paper to a specific line number.
This is achieved by using the top margin and the first 11 tab
settings from the Set Vertical Format command to specify 12
vertical channels. The first channel is always the top margin,
even if no tabs have been set.
04
Control sequence prefix of a Vertical Channel
Select command
vv
Byte that selects the channel where you want to
move the print position.
The correlations between valid values and the
channel selection are:
7A = 10
7B = 11
7C = 12
81 = 1
82 = 2
83 = 3
84 = 4
85 = 5
86 = 6
87 = 7
88 = 8
89 = 9
A Vertical Channel Select (VCS) command is interpreted as a one
Line Feed (LF) command. This means that if you want to print
2-20
XEROX MRP FAMILY COAX COMMAND REFERENCE